Timeguard Catalogue 2025

Safety 88

Weathersafe Vision

See pages 52 & 53 for Product Information.

TGV101N

TGV103N

TGV105NP

Vision

Vision

Vision

Weathersafe Range

Switched Socket

Fused Spur

RCD Fused Spur

Type

• •

• •

• •

IP Rating

Operating Voltage

230V AC

1

Rocker Switch Poles Rocker Switch Rating Operating Temperature Integral BS1362 Fuse

230V 13 Amp (3kW)

-5°C to 55°C

-5°C to 55°C

-5°C to 55°C

• • •

Trip Speed RCD Contact Break

BS7288 – 40ms Double Pole

Lost Neutral & Pulsating DC Earth Fault

Continues to Protect with

• •

• •

• •

Cable Capacity EC Directives Registered Design Number

3x 2.5mm² Conforms to Latest Directives

000522784-0003

000522784-0003

Height Width Depth

148 108 75.5

148 108 75.5

160 115

Dimensions (mm)

90

See pages 53 & 54 for Product Information.

TGV201N

TGV204NP

TGV205NP

Vision

Vision

Vision

Weathersafe Range

Switched Socket

Switched RCD Socket - Passive

Switched RCD Socket - Active

Type

IP66

IP66

IP66

IP Rating

Operating Voltage Rocker Switch Poles Rocker Switch Rating Operating Temperature Trip Speed RCD Contact Break

230V AC

1

1

1

230V 13 Amp (3kW)

-5° to 55°C

-5° to 40°C

-5° to 40°C

• •

• •

BS7288 – 40ms Double Pole

Lost Neutral & Pulsating DC Earth Fault

Continues to Protect with

• •

• •

• •

Cable Capacity EC Directives

3x 2.5mm²

Conforms to Latest Directives

000522784-0004

000522784-0004

000522784-0004

Registered Design Number

148 165 75.5

148 165 75.5

148 165 75.5

Width Height Depth

Dimensions (mm)

See page 52 for Product Information.

FSTWIFITUTGV

24 Hour/7 Day with Boost

Timer Mode Setting Type App Availability

Wi-Fi Controlled Via Tuya Smart App

Android and iOS •

App Supports Wi-Fi Specification Frequency Range Boost Duration Switch Type Controls LED Lighting Operating Voltage Switch Rating Operating Temperature IP Rating

GHz b/g/n Multiple devices and users

2.4 2.412 – 2.484 Custom Setting In Tuya Smart

GHz

Double Pole (Isolation Switch) Max

500W IP66

• • • • •

230V AC 13A Resistive (3kW) 0°C to 40°C

Integral BS1362 Fuse & DP Switch

EC Directives

Conforms to Latest Directives Height

160 115 90

Dimensions (mm)

Width Depth

Note: FSTWIFITUTGV can be used with up to 5A of inductive loads, 1000W incandescent/halogen, 100W CFL and 500W fluorescent and LED lighting. Cannot be used with discharge lighting.

sales office 020 8452 1112

Made with FlippingBook - professional solution for displaying marketing and sales documents online