Timeguard Catalogue 2025
87 Safety
Valiance+ RCD Protection
See page 48 & 49 for Product Information.
RCD01WAVN
RCD02WPVN Latching (Passive)
RCD03MAVN
RCD04MPVN Latching (Passive)
Non-Latching (Active)
Non-Latching (Active)
Latching or Non-Latching
Type
Operating Voltage
230V AC
• • • • • •
• • • • • •
• • • • •
• • • • •
Current Rating
30mA BS7288 – 40ms Double Pole 250A (Earth Leakage) Lost Neutral & Pulsating DC Earth Fault 3x 2.5mm² Flexible: 10.5mm diameter max Fully Complies with BS1363 Conforms to Latest Directives
Rated Trip Current Trip Speed Contact Break Breaking Capacity
•
•
•
•
Continues to Protect with
•
•
•
•
Cable Capacity
EC Directives
•
•
•
•
85 85 42 25
85 85 42 25
88 88 60 40
88 88 60 40
Height Width Depth
Dimensions (mm)
Surface Mount Wall Box Min. Box Depth (mm)
Supplied
•
•
Note: Metal RCD Sockets supplied with a 40mm BS metal surface wall box.
See page 49 & 50 for Product Information.
RCD05WAVN
RCD06WPVN Latching (Passive)
RCD07MAVN
RCD08MPVN Latching (Passive)
Latching or Non-Latching 230V AC Fully Complies with BS1363 30mA BS7288 – 40ms Double Pole 250A (Earth Leakage) Lost Neutral & Pulsating DC Earth Fault 3x 2.5mm² Conforms to Latest Directives
Type
Non-Latching (Active)
Non-Latching (Active)
• • • • • •
• • • • • •
• • • • • •
• • • • • •
Operating Voltage Current Rating Rated Trip Current Trip Speed Contact Break Breaking Capacity
•
•
•
•
Continues to Protect with
• •
• •
• •
• •
Cable Capacity EC Directives
Height Width Depth
85
85
88
88
145
145
148
148
Dimensions (mm)
43 25
43 25
60 40
60 40
Min. Box Depth (mm) Surface Mount Wall Box
•
•
Supplied
Note: Metal RCD Sockets supplied with a 40mm BS metal surface wall box.
See page 51 for Product Information.
RCD10WPVN Latching (Passive)
RCD11WPVN Latching (Passive)
RCD16MLN
CUFMS100
Latching (Passive)
Latching or Non-Latching 230V AC Fully Complies with BS1363 30mA BS7288 – 40ms Double Pole 250A (Earth Leakage) Lost Neutral & Pulsating DC Earth Fault 3x 2.5mm² Flexible: 10.5mm diameter max Width Depth Height Conforms to Latest Directives
Type Operating Voltage
• • • • • •
• • • • • •
• • • • • •
•
Current Rating
Rated Trip Current Trip Speed Contact Break Breaking Capacity
•
Continues to Protect with
•
•
•
Cable Capacity
•
•
•
EC Directives
85 85 52 25
85 85 42 35
87 87 60 40
78
120
Dimensions (mm)
64
Surface Mount Wall Box Supplied with 1x100A and 1x80A HRC fuses Min. Box Depth (mm) Supplied
•
Note: Metal RCD Sockets supplied with a 40mm BS metal surface wall box.
email sal e s.ce@deta.co.uk visit our website timeguard.com
Made with FlippingBook - professional solution for displaying marketing and sales documents online