Scame Industrial Connectors Catalogue
COMMAND Series
-
-
-
-
12
60
160 K2 K3 K4 K6 K5 Switch size 200 250 315 400 500 630 800 1000 1250
400
800
400
630
120
105
1000
1600
1600
1600
1250
1600
1250
1250
6300
5040
1600 (*)
2x (80x102)
-
12
35
70
800
400
630
100
100
73.5
1000
1250
1250
1250
1250
1250
1250
1250
1250
6300
5040
1000
2x (50x8)
-
12
35
70
90
800
400
525
100
73.5
1000
1000
1000
1000
1000
1000
1000
1000
1000
6300
5040
1000
2x (50x6)
12
35
70
70
800
800
800
800
800
800
800
800
800
400
420
800
100
73.5
1000
6300
5040
2x240
2x (50x5)
12
53
30
50
40
630
630
630
630
630
630
630
630
500
400
330
630
26.5
1000
6300
5040
2x185
2x (32x6)
12
13
26
26
50
30
500
500
500
500
500
400
400
500
315
250
210
400
1000
4000
3200
2x150
2x (25x4)
12
13
26
26
50
30
400
400
400
400
400
400
400
400
315
250
200
400
1000
4000
3200
2x150
2x (25x4)
12
13
26
26
50
25
315
315
315
315
315
315
315
315
250
200
165
315
185
1000
3150
2520
2x (25x4)
8
12
16
50
25
250
250
250
250
250
250
250
250
200
160
130
250
120
13.5
20x5
1000
2500
2000
8
12
16
50
20
200
200
200
200
200
200
200
200
160
125
105
200
120
13.5
20x5
1000
2000
1600
8
12
85
16
16
160
160
160
160
160
160
160
160
125
100
160
100
120
13.5
20x5
1000
1600
1280
mm 2
(V)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
kW
mm
(kV)
(kA)
(kA)
(kA)
(kA)
(kA)
Mixed resistive and inductive loads, 500V including moderate overloads 690V AC23A 415V
Rated operational current – Ie Switching of motor loads or other highly 500V inductive loads (3 phase / 3 pole) 690V AC23A Rated operational power (°) 415V Rated making capacity 415V AC23
Impulse withstand voltage Rated thermal current AC21A 415V
Resistive loads, including 500V moderate overloads 690V AC22A 415V
Rated fuse short-circuit Short circuit withstand current 0.25 sec Short circuit making capacity 415V Back up fuse R.M.S value Peak value Flexible wire current
Rated breaking capacit 415V AC23
Rated insulation voltage Rated current In TECHNICAL CHARACTERISTICS 3P, 3P+N
Short circuit withstand current 1sec
Bars dimension
(*) Neutral pole 1250A Full current neutral pole available on request. (°) This values are given for guidance and may vary according to the specifics provided by the motor manufacturer.
Rated current: 160A-200A-250A-315A-400A 500A-630A-800A-1000A 1250A-1600A (*) Protection degree: IP65 (front operator) Operating ambient
Polarity: 3P-3P+N
ambient temperature: +60°C
temperature according to the reference standard: -25°C +40°C Max operating
EN 60947-3
and fuse-combination unit.
Low voltage switchgear and controlgear. Part 3: switches, disconnectors, switch-disconnectors
REFERENCE STANDARDS HIGH RATING SWITCH DISCONNECTORS - 160A-1600A
TECHNICAL CHARACTERISTICS
3P+N with late break early make neutral pole. Front operators box version equipped with door locking in ON position. Padlockable handle. Full current neutral pole up to 1250A. (*) Neutral pole 1250A. Full current neutral pole available on request.
Switch size K2 Box version (B) Base mounting screws fixing Switch size K3 Box version (B)
Base mounting screws fixing Switch size K4 Box version (B)
Base mounting screws fixing Switch size K5 Box version (B)
Base mounting screws fixing Switch size K6 Box version (B)
Base mounting screws fixing
VERSIONS
COMMAND Series
Made with FlippingBook - professional solution for displaying marketing and sales documents online