Scame Industrial Connectors Catalogue

COMMAND Series

-

-

-

-

12

60

160 K2 K3 K4 K6 K5 Switch size 200 250 315 400 500 630 800 1000 1250

400

800

400

630

120

105

1000

1600

1600

1600

1250

1600

1250

1250

6300

5040

1600 (*)

2x (80x102)

-

12

35

70

800

400

630

100

100

73.5

1000

1250

1250

1250

1250

1250

1250

1250

1250

6300

5040

1000

2x (50x8)

-

12

35

70

90

800

400

525

100

73.5

1000

1000

1000

1000

1000

1000

1000

1000

1000

6300

5040

1000

2x (50x6)

12

35

70

70

800

800

800

800

800

800

800

800

800

400

420

800

100

73.5

1000

6300

5040

2x240

2x (50x5)

12

53

30

50

40

630

630

630

630

630

630

630

630

500

400

330

630

26.5

1000

6300

5040

2x185

2x (32x6)

12

13

26

26

50

30

500

500

500

500

500

400

400

500

315

250

210

400

1000

4000

3200

2x150

2x (25x4)

12

13

26

26

50

30

400

400

400

400

400

400

400

400

315

250

200

400

1000

4000

3200

2x150

2x (25x4)

12

13

26

26

50

25

315

315

315

315

315

315

315

315

250

200

165

315

185

1000

3150

2520

2x (25x4)

8

12

16

50

25

250

250

250

250

250

250

250

250

200

160

130

250

120

13.5

20x5

1000

2500

2000

8

12

16

50

20

200

200

200

200

200

200

200

200

160

125

105

200

120

13.5

20x5

1000

2000

1600

8

12

85

16

16

160

160

160

160

160

160

160

160

125

100

160

100

120

13.5

20x5

1000

1600

1280

mm 2

(V)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

kW

mm

(kV)

(kA)

(kA)

(kA)

(kA)

(kA)

Mixed resistive and inductive loads, 500V including moderate overloads 690V AC23A 415V

Rated operational current – Ie Switching of motor loads or other highly 500V inductive loads (3 phase / 3 pole) 690V AC23A Rated operational power (°) 415V Rated making capacity 415V AC23

Impulse withstand voltage Rated thermal current AC21A 415V

Resistive loads, including 500V moderate overloads 690V AC22A 415V

Rated fuse short-circuit Short circuit withstand current 0.25 sec Short circuit making capacity 415V Back up fuse R.M.S value Peak value Flexible wire current

Rated breaking capacit 415V AC23

Rated insulation voltage Rated current In TECHNICAL CHARACTERISTICS 3P, 3P+N

Short circuit withstand current 1sec

Bars dimension

(*) Neutral pole 1250A Full current neutral pole available on request. (°) This values are given for guidance and may vary according to the specifics provided by the motor manufacturer.

Rated current: 160A-200A-250A-315A-400A 500A-630A-800A-1000A 1250A-1600A (*) Protection degree: IP65 (front operator) Operating ambient

Polarity: 3P-3P+N

ambient temperature: +60°C

temperature according to the reference standard: -25°C +40°C Max operating

EN 60947-3

and fuse-combination unit.

Low voltage switchgear and controlgear. Part 3: switches, disconnectors, switch-disconnectors

REFERENCE STANDARDS HIGH RATING SWITCH DISCONNECTORS - 160A-1600A

TECHNICAL CHARACTERISTICS

3P+N with late break early make neutral pole. Front operators box version equipped with door locking in ON position. Padlockable handle. Full current neutral pole up to 1250A. (*) Neutral pole 1250A. Full current neutral pole available on request.

Switch size K2 Box version (B) Base mounting screws fixing Switch size K3 Box version (B)

Base mounting screws fixing Switch size K4 Box version (B)

Base mounting screws fixing Switch size K5 Box version (B)

Base mounting screws fixing Switch size K6 Box version (B)

Base mounting screws fixing

VERSIONS

COMMAND Series

Made with FlippingBook - professional solution for displaying marketing and sales documents online