WAGO Rail-Mount Terminal Blocks TOPJOB® S

Technical Data 0.5 … 6 (10) mm² 1 800 V/8 kV/3 2

1 Conductor range: 0.5 … 10 mm² “s+f-st”; Push-in termination: 2.5 … 10 mm² “s” and 2.5 … 6 mm² “insulated ferrules; 12 mm” Depending on the conductor characteristic, a conduc tor with a smaller cross section can also be inserted via push-in termination. 2 800 V = rated voltage 8 kV = rated impulse voltage 3 = pollution degree Please observe the application notes:

20 … 8 AWG 600 V, 30 A U

I N 30 A 600 V, 30 A 2 Terminal block width: 15 mm / 0.591 inch L 13 … 15 mm / 0.51 … 0.59 inch

H 2

H 1

LED/Neon lamp green

LED/Neon lamp red

Jumpers, from page 169 Marking, from page 266 Approvals and corresponding ratings, visit www.wago.com

F 1

T 1

K 2

K 1

Operating condition Slide link closed, auxiliary circuit grounded, green LED/neon lamp illuminates.

32,9 mm/ 1.3 in

38,2 mm/1.5 in

96,3 mm/3.79 in

IEC 60204/DIN VDE 0113 “Safety of machinery – Electrical equipment of machines – Part 1: General requirements,” Section 9.4.3.1: Ground faults on control circuits must not cause uninten tional starting, hazardous movements, or prevent stopping of the machine. In order to fulfill this requirement, a connection to the pro tective bonding circuit must be provided in accordance with Section 8.2 and the devices must be connected as described in Section 9.1.4. Control circuits fed from a transformer and not connected to the protective bonding circuit must be provided with an insulation monitoring device (e.g., residual current device), which either indi cates a ground fault or interrupts the circuit automatically after a ground fault. In the case of electronic circuits, the connection of one side of the control circuit to the protective bonding circuit in accordance with Section 9.1.4 can prevent unintentional operation. When this does not help, or if due to other rea sons that electronic circuits cannot be connected to the protective bonding circuit, other measures must be taken to achieve the same level of safety. Multipole control switches that interrupt all live conduc tors must be used where the control circuit is directly con nected between the phase conductors of the supply or between a phase conductor and a neutral conductor, which is either not grounded or grounded through a high impedance. This is required for starting or stopping machine functions, which can cause a hazardous situation including: damaging the machine or halting work in prog ress in the event of unintentional starting or failure to stop.

2-conductor through terminal block; with test point; same profile as 2-conductor disconnect terminal block Color Item No. Pack. Unit gray 2006-1601 25 blue 2006-1604 25

H 2

H 1

LED/Neon lamp green

LED/Neon lamp red

Other terminal blocks with the same profile: Carrier 2006‑1661

Page 106 Page 108 Page 106

F 1

Fuse

2006‑1681 2006‑1671

T 1

K 2

K 1

Disconect

Accessories; item-specific Push-in type jumper bar; insulated; I N 41 A; light gray 2-way 2006-402 25 3-way 2006-403 25 4-way 2006-404 25 5-way 2006-405 25 Push-in type jumper bar; insulated; I N 41 A; light gray 1 to 3 2006-433 25 1 to 4 2006-434 25 1 to 5 2006-435 25 Star point jumper; insulated; I N = I N terminal block; light gray 1-3-5 2006-405/011-000 25

Test condition – no grounding Slide link open, auxiliary circuit not grounded.

H 2

H 1

LED/Neon lamp green

LED/Neon lamp red

F 1

T 1

K 2

K 1

Test condition – grounding Slide link open, auxiliary circuit not grounded, red LED/neon lamp illuminates.

Double-deck marker carrier; pivoting gray 2002-121

50 (25)

Ground conductor disconnect terminal block – top view

WAGO Rail-Mount Terminal Blocks TOPJOB® S