TimeGuard Product Catalogue

Safet y

Safet y

88

89

Tr ipf as t & Val iance RCD Protec t ion

Weather safe V i sion

See pages 52 – 53 for Product Information.

See pages 55 – 56 for Product Information.

TFA01W

TFP02WL

TFA03M

TFP04ML

TFA05W

TFP06WL

TFA07M

TFP08ML

TFP10WL

TGV101N

TGV104N

TGV103N

Type

Active • • • • •

Passive • • • • •

Active • • • • •

Passive • • • • •

Active • • • • •

Passive • • • • •

Active • • • • •

Passive • • • • •

Passive • 13A

Latching or Non-Latching

Weathersafe Range Type Weatherproof Rating

Vision

Vision

Vision

Operating Voltage

230V AC

Switched Socket • • 1

RCD Fused Spur • •

Fused Spur • •

Current Rating

Fully Complies with BS1363

IP66

Rated Trip Current

• • •

30mA

Operating Voltage

230V AC

Trip Speed

BS7288 – 40ms

Rocker Switch Poles Rocker Switch Rating

Contact Break

Double Pole

230V 13 Amp (3kW)

• •

Lost Neutral & Pulsating DC Earth Fault

Operating Temperature

-5°C to 55°C

0° to 40°C • • •

• •

Continues to Protect with

Integral BS1362 Fuse Trip Speed

Up to 10.5mm 2 •

3x 2.5mm 2

Cable Capacity

• •

• • 8

• •

• •

• • 85 146 20 •

• • 85 146 20 •

• • 87 148 55

• • 87 148 55

BS7288 – 40ms

EC Directives

Conforms to Latest Directives Height

RCD Contact Break

Double Pole

85 85 20 •

87 87 55

87 87 55

85 85 20 •

Lost Neutral & Pulsating DC Earth Fault

Continues to Protect with

Dimensions (mm)

85 20 •

Width Depth

3x 2.5mm 2

Cable Capacity

• • 000522784-0003 142.5 117 75.5

• • 000522784-0003 142.5 117 75.5

• • 000522784-0003 142.5 117 75.5

Min. Box Depth

25mm

EC Directives

Conforms to Latest Directives

Surface Mount Wall Box

Supplied

Registered Design Number

Height

Note: Metal RCD Sockets supplied with a 40mm BS metal surface wall box.

Dimensions (mm)

Width Depth

See page 53 for Product Information.

See pages 56 – 57 for Product Information.

RCD05WAV

RCD06WPV

RCD07MAV

RCD08MPV

TGV201N

TGV204N

TGV205N

Type

Active • • • • •

Passive • • • • •

Active • • • • •

Passive • • • • •

Latching or Non-Latching

Weathersafe Range Type Weatherproof Rating

Vision

Vision

Vision

Operating Voltage

230V AC

Switched Socket • • 1

Switched RCD Socket – Passive • • 1

Switched RCD Socket – Active • • 1

Current Rating

Fully Complies with BS1363

IP66

Rated Trip Current

30mA

Operating Voltage

230V AC

Trip Speed

BS7288 – 40ms

Rocker Switch Poles Rocker Switch Rating

Contact Break

Double Pole

230V 13 Amp (3kW)

• •

• • • •

• • • •

Lost Neutral & Pulsating DC Earth Fault

Operating Temperature

0°C to 40°C

Continues to Protect with

Trip Speed

BS7288 – 40ms

3x 2.5mm 2

Cable Capacity

• • 86 147 42.5 •

• • 86 147 42.5 •

• • 87 148 56

• • 87 148 56

RCD Contact Break

Double Pole

EC Directives

Conforms to Latest Directives Height

Lost Neutral & Pulsating DC Earth Fault

Continues to Protect with

Dimensions (mm)

Width Depth

3x 2.5mm 2

Cable Capacity

• • 000522784-0004 142.5 157 75.5

• • 000522784-0004 142.5 157 75.5

• • 000522784-0004 142.5 157 75.5

EC Directives

Conforms to Latest Directives

Min. Box Depth

25mm

Registered Design Number

Surface Mount Wall Box

Supplied

Height

Dimensions (mm)

Width Depth

Note: Metal RCD Sockets supplied with a 40mm BS metal surface wall box.

See page 55 for Product Information.

See pages 53 – 54 for Product Information.

FSTWIFITGV

RCD10WPV

RCD16ML

CB008

Timer Mode Setting Type App Availability App Supports

Boost Wi-Fi and 4G (Controlled by App) Android and iOS • 2.4 2.412 – 2.484 1 and 2 • 500W IP66

Type

Passive • • • • •

Passive • 13A

Active • • • BS7071 – 40ms •

Latching or Non-Latching

Operating Voltage

230V AC

Current Rating

Fully Complies with BS1363

Multiple devices and users

Rated Trip Current

• • •

30mA

Wi-Fi Speci cation

GHz b/g/n

Trip Speed

BS7288 – 40ms

Frequency Range

GHz

Contact Break

Double Pole

Boost Duration Switch Type

Lost Neutral & Pulsating DC Earth Fault

Continues to Protect with

Single Pole ON/OFF

Controls LED Lighting

Max.

Up to 10.5mm 2 •

3x 2.5mm 2

Cable Capacity

• •

Weatherproof Rating Operating Voltage

EC Directives

• 127

Conforms to Latest Directives Height

• • • • •

230V AC

85 85 49.6 •

85 85 30

Switch Rating 230V AC

13A Resistive (3kW)

Dimensions (mm)

60 70

Width Depth

Operating Temperature

0°C to 40°C

Integral BS1362 Fuse & DP Switch EC Directives

Min. Box Depth

25mm

Conforms to Latest Directives Height

Surface Mount Wall Box

Supplied

85 85 44

Note: Metal RCD Sockets supplied with a 40mm BS metal surface wall box.

Dimensions (mm)

Width Depth

Note: FSTWIFITGV can be used with up to 5A of inductive loads, 1000W incandescent/halogen, 100W CFL and 500W uorescent and LED lighting. Cannot be used with discharge lighting.

sales office 020 8452 1112

fax 020 8450 0635

email csc @ timeguard.com

visit our website timeguard.com

Made with FlippingBook - Online Brochure Maker