TimeGuard Product Catalogue
82 L ight
L ight
83
Secur i t y L ight & Time Delay Swi tches
PIR L ight ing Control ler s & LED L ight ing
See pages 22 – 23 for Product Information.
See page 27 for Product Information.
theMova S360 • 1 Channel
thePrema S360 • 1 Channel 60W
theLuxa S150 • 1 Channel
theLuxa S180 • 1 Channel
theLuxa S360 • 1 Channel 25W 90W 100W 2300 400VA IP55 12 • 1 20 • 5 – 1000 • 100 x 85 x 136.5
DS1/DSS • 10W* 1.5kW 20 – 200W
DS2 • 10W 1.5kW 20 – 200W
DS4 • 80W 1.4kW
DS3HD • 150W 4kW 20 – 200W
Operating Voltage
230V AC
Switch Type
Single
1 or 2 Channel
Controls LED Lighting
Max. Filament Lamps
25W 70W 80W 2300 1150VA IP40 7 •
25W 90W 100W 2300 400VA IP55 12 150° 1 20 • 5 – 1000 • 99.6 x 85 x 127
25W 90W 100W 2300 400VA IP55 12 180° 1 20 • 5 – 1000 • 99.6 x 85 x 127
<2W
Controls LED Lighting
180W 200W 2300 1150VA IP40 64 •
2 – 8W >8W
Permissible Loads
Low Voltage Fluorescent
700W 10 Seconds 10 Minutes
1st Channel Filament/Halogen Loading (W) 1st Channel Fluorescent/Low Energy Loading (W) Weatherproof Rating Detection Metres (max.) Angle of Detection 360° Light ON Time after last Seconds (min.) Detection (Adjustable) Minutes (max.) Permanent ON Facility Electronic Adjustable Light Level Control LUX EC Directives
10 Seconds 10 Minutes
3 Seconds 2 Hours
2 Minutes 3 Hours
Minimum (approx.) Maximum (approx.)
Adjustable Time Delay
Operating Voltage
• • •
• • •
• • •
• • • • • 94 x 94 x 57
230V AC
Operating Temperature
-10°C to 40°C
Light ON Time
Adjustable
10 60 • 30 – 3000 • 97 x 60 x 60
10 60 • 5 – 3000 • 77 x 110 x 110
Weatherproof Rating
IP65
EC Directives
• 86 x 86 x 20
• 86 x 86 x 20
• 85 x 85 x 45
Conforms to Latest Directives
Dimensions (mm)
Height x Width x Depth
Note: DS2 heating load 2kW, inductive 4A, motor 1hp. RLS010 remote control range 8m (uses 3x AAA batteries – not supplied). * The DS1 and DSS need to be permanently powered which is achieved through the switched Live. As such, some LED and CFL lamps may glow or ash whilst this product is in the ‘OFF’ position. This glow/ ash can be eliminated by adding the Timeguard ZV900 Automatic Switch Load Controller to the circuit. The LED switching capabilities of all these products can be increased up to 200W with the addition of the Timeguard ZV900 Automatic Switch Load Controller. The ZV900 is sold separately.
Conforms to Latest Directives
Dimensions (mm)
Height x Width x Depth
See pages 28 – 29 for Product Information.
See pages 20 – 21 for Product Information.
MLB3000 MLW3000 • 500 3000 140W • 12 200°
MLTP180BK MLTP180WH • 500 2300 500W • 12 180°
SLB2300 SLW2300 • 500 2300 250W • 12 180°
SLB2300RF SLW2300RF • 500 2300 250W • 12 180°
SLW2400
MTLW3000
MLSA360N
NSLDD1000
HF1 High Frequency Detector (Microwave) – 1 Channel 1000W
HF2R High Frequency Detector (Microwave) – 1 Channel 1000W 100W 440VA • 7.5m Diameter •
Switch Type Filament/Halogen Loading Controls LED Lighting
Operating Voltage
230V AC
• 500 2000
• 500 3000 140W • 12 200°
• 500 3000 140W IP45 12 360°
• 500 3000 80W* •
Fluorescent/Low Energy Filament
Lamp Load (W)
Max.
Fluorescent & Low Energy Lighting Weatherproof Rating IP20 Detection
500VA • 6m Diameter • 3 30 • • • • 118 x 118 x 50
Controls LED Lighting Weatherproof Rating
IP55
IP44 12 180°
Metres (max.)
Detection Range
Metres (max.)
Dusk to Dawn Dusk to Dawn 2 to 8 Hours or Dawn
Angle of Detection
360°
Angle of Detection
360°
Light ON Time after last
30 30
Seconds (min.)
Dusk to Timed OFF
Selectable
Detection (Adjustable)
Minutes (max.)
Light ON Time after last
Seconds (min.)
5 18
5 18
5 18
5 12
2 30
5 15
3 18
Permanent ON Facility
• • • • 90 x 90 x 41
Electronic
Detection (Adjustable)
Minutes (max.)
Light Level Sensing
Adjustable
Permanent ON Facility
Electronic
• •
• •
• •
• •
• •
• •
• •
• • • • 3 Year 93 x 78 x 141
Concealed Front Panel EC Directives
Adjustable Light Level Control Remote Control
Conforms to Latest Directives
LEDPROFOB
Dimensions (mm)
Height x Width x Depth
EC Directives
Conforms to Latest Directives
• 3 Year 73 x 87 x 121
• 5 Year 73 x 87 x 121
• 3 Year 135 x 70 x 125
• 3 Year 95 x 80 x 125
• 3 Year 95 x 80 x 45
• 3 Year 82 x 82 x 67
• 3 Year 93 x 78 x 141
Guarantee Dimensions (mm)
Height x Width x Depth
Note: *The LED switching capabilities of this product can be increased up to 200W with the addition of the Timeguard ZV900 Automatic Switch Load Controller. The ZV900 is sold separately.
See page 26 for Product Information.
ZV210 Single/2 Way 300W
ZV215 Double/2 Way 300W
ZV810 Single/2 Way 500W
ZV900 Power Supply 1000W 6A 5A 3 to 200W LED 3 to 200W
ZV700B Single/2 Way 400W
See pages 30 – 31 for Product Information.
Switch Type
Single or Double Gang
Filament Load
40W min. up to max. Resistive (max.) Inductive (max.) LED Low Energy Low Voltage Fluorescent (max.)
LEDPROSLB LEDPROSLWH •
LEDPRORFKB LEDPRORFKWH •
LEDPROPCB LEDPROPCWH •
LEDPRO10B
LEDPRO10WH
LEDPRO20B
LEDPRO20WH
LEDPRO30B
LEDPRO30WH
LEDPRO50B
LEDPRO50WH
Operating Voltage
230V AC
• 10 650
• 10 750
• 20 1400
• 20 1500
• 30 2050
• 30 2100
• 50 3500
• 50 3600
Output Load Capability
20W 11 to 150W 20 to 200W 18 to 76W • (Optional)
20W Up to 85W with adaptor FLA01 *
20W Up to 85W with adaptor FLA01 *
20W 40 to 150W 15 to 150W* 18 to 150W
Maximum Light Load
Internal (W)
LED Brightness
Minimum Lumen
Optional Modes
Dusk to Dawn/Permanent ON/Test
• IP55 12 180° 3 18 2 to 1000
• IP55 12 180° 3 18 2 to 1000
• IP55
• • • •
• • • •
76W
Weatherproof Rating
IP65
•
•
•
•
•
•
•
•
Light Level Sensing Light ON Time
• • •
Detection Range
Metres (max.)
• •
Adjustable
Angle of Detection Light ON Time after last
Weatherproof Rating
• 2x 1mm Solid Core Cable, 2x 1mm Twin and Earth Flat Cable <1W 110mm •
IP20
Seconds (min.)
Cable Provision Power Consumption Fixing Hole Centres Operating Temperature Concealed Front Panel EC Directives
Detection (Adjustable)
Minutes (max.)
Adjustable Light Level Control (LUX) Remote Control
LEDPROFOB
• • 114x78x127
0° to 40°C
EC Directives
Conforms to Latest Directives
• 155x117x60
• 155x117x60
• 205x158x63
• 205x158x63
• 265x197x66
• 265x197x66
• 335x252x69
• 335x252x69
• 91x78x73
• 114x78x127
Dimensions (mm)
Height x Width x Depth
• 115 86 x 86 x 50
• 122 86 x 86 x 22
• 122 86 x 86 x 22
• 135 86 x 86 x 38
•
Conforms to Latest Directives Height (Open)
Dimensions (mm)
28 x 119 x 42
Height (Closed) x Width x Depth
Note: Cannot be used with dimmer or other electronic switches in two way switching systems or replace an intermediate switch in three or more way switching systems. Unsuitable for use with discharge and LED lighting. These products need to be permanently powered which is achieved through the switched Live. As such, some LED and CFL lamps may glow or ash whilst this product is in the ‘OFF’ position. This glow/ ash can be eliminated by adding the Timeguard ZV900 Automatic Switch Load Controller to the circuit. The LED switching capabilities of this product can be increased up to 200W by the addition of the Timeguard ZV900 Automatic Switch Load Controller. The ZV900 is sold separately. *ZF810 Philips or Osram bulbs only. ZV900: Speci cally designed to operate with Timeguard ZV700, ZV700B, ZV210, ZV215, DS1, ZV810, NMT01, NTM02, NTT01, NTT02, NTT03, NTT04, NTT05, NTT06, NTT07 and NTT08 when used with LED or CFL lighting.
sales office 020 8452 1112
fax 020 8450 0635
email csc @ timeguard.com
visit our website timeguard.com
Made with FlippingBook - Online Brochure Maker