TimeGuard Product Catalogue

82 L ight

L ight

83

Secur i t y L ight & Time Delay Swi tches

PIR L ight ing Control ler s & LED L ight ing

See pages 22 – 23 for Product Information.

See page 27 for Product Information.

theMova S360 • 1 Channel

thePrema S360 • 1 Channel 60W

theLuxa S150 • 1 Channel

theLuxa S180 • 1 Channel

theLuxa S360 • 1 Channel 25W 90W 100W 2300 400VA IP55 12 • 1 20 • 5 – 1000 • 100 x 85 x 136.5

DS1/DSS • 10W* 1.5kW 20 – 200W

DS2 • 10W 1.5kW 20 – 200W

DS4 • 80W 1.4kW

DS3HD • 150W 4kW 20 – 200W

Operating Voltage

230V AC

Switch Type

Single

1 or 2 Channel

Controls LED Lighting

Max. Filament Lamps

25W 70W 80W 2300 1150VA IP40 7 •

25W 90W 100W 2300 400VA IP55 12 150° 1 20 • 5 – 1000 • 99.6 x 85 x 127

25W 90W 100W 2300 400VA IP55 12 180° 1 20 • 5 – 1000 • 99.6 x 85 x 127

<2W

Controls LED Lighting

180W 200W 2300 1150VA IP40 64 •

2 – 8W >8W

Permissible Loads

Low Voltage Fluorescent

700W 10 Seconds 10 Minutes

1st Channel Filament/Halogen Loading (W) 1st Channel Fluorescent/Low Energy Loading (W) Weatherproof Rating Detection Metres (max.) Angle of Detection 360° Light ON Time after last Seconds (min.) Detection (Adjustable) Minutes (max.) Permanent ON Facility Electronic Adjustable Light Level Control LUX EC Directives

10 Seconds 10 Minutes

3 Seconds 2 Hours

2 Minutes 3 Hours

Minimum (approx.) Maximum (approx.)

Adjustable Time Delay

Operating Voltage

• • •

• • •

• • •

• • • • • 94 x 94 x 57

230V AC

Operating Temperature

-10°C to 40°C

Light ON Time

Adjustable

10 60 • 30 – 3000 • 97 x 60 x 60

10 60 • 5 – 3000 • 77 x 110 x 110

Weatherproof Rating

IP65

EC Directives

• 86 x 86 x 20

• 86 x 86 x 20

• 85 x 85 x 45

Conforms to Latest Directives

Dimensions (mm)

Height x Width x Depth

Note: DS2 heating load 2kW, inductive 4A, motor 1hp. RLS010 remote control range 8m (uses 3x AAA batteries – not supplied). * The DS1 and DSS need to be permanently powered which is achieved through the switched Live. As such, some LED and CFL lamps may glow or ash whilst this product is in the ‘OFF’ position. This glow/ ash can be eliminated by adding the Timeguard ZV900 Automatic Switch Load Controller to the circuit. The LED switching capabilities of all these products can be increased up to 200W with the addition of the Timeguard ZV900 Automatic Switch Load Controller. The ZV900 is sold separately.

Conforms to Latest Directives

Dimensions (mm)

Height x Width x Depth

See pages 28 – 29 for Product Information.

See pages 20 – 21 for Product Information.

MLB3000 MLW3000 • 500 3000 140W • 12 200°

MLTP180BK MLTP180WH • 500 2300 500W • 12 180°

SLB2300 SLW2300 • 500 2300 250W • 12 180°

SLB2300RF SLW2300RF • 500 2300 250W • 12 180°

SLW2400

MTLW3000

MLSA360N

NSLDD1000

HF1 High Frequency Detector (Microwave) – 1 Channel 1000W

HF2R High Frequency Detector (Microwave) – 1 Channel 1000W 100W 440VA • 7.5m Diameter •

Switch Type Filament/Halogen Loading Controls LED Lighting

Operating Voltage

230V AC

• 500 2000

• 500 3000 140W • 12 200°

• 500 3000 140W IP45 12 360°

• 500 3000 80W* •

Fluorescent/Low Energy Filament

Lamp Load (W)

Max.

Fluorescent & Low Energy Lighting Weatherproof Rating IP20 Detection

500VA • 6m Diameter • 3 30 • • • • 118 x 118 x 50

Controls LED Lighting Weatherproof Rating

IP55

IP44 12 180°

Metres (max.)

Detection Range

Metres (max.)

Dusk to Dawn Dusk to Dawn 2 to 8 Hours or Dawn

Angle of Detection

360°

Angle of Detection

360°

Light ON Time after last

30 30

Seconds (min.)

Dusk to Timed OFF

Selectable

Detection (Adjustable)

Minutes (max.)

Light ON Time after last

Seconds (min.)

5 18

5 18

5 18

5 12

2 30

5 15

3 18

Permanent ON Facility

• • • • 90 x 90 x 41

Electronic

Detection (Adjustable)

Minutes (max.)

Light Level Sensing

Adjustable

Permanent ON Facility

Electronic

• •

• •

• •

• •

• •

• •

• •

• • • • 3 Year 93 x 78 x 141

Concealed Front Panel EC Directives

Adjustable Light Level Control Remote Control

Conforms to Latest Directives

LEDPROFOB

Dimensions (mm)

Height x Width x Depth

EC Directives

Conforms to Latest Directives

• 3 Year 73 x 87 x 121

• 5 Year 73 x 87 x 121

• 3 Year 135 x 70 x 125

• 3 Year 95 x 80 x 125

• 3 Year 95 x 80 x 45

• 3 Year 82 x 82 x 67

• 3 Year 93 x 78 x 141

Guarantee Dimensions (mm)

Height x Width x Depth

Note: *The LED switching capabilities of this product can be increased up to 200W with the addition of the Timeguard ZV900 Automatic Switch Load Controller. The ZV900 is sold separately.

See page 26 for Product Information.

ZV210 Single/2 Way 300W

ZV215 Double/2 Way 300W

ZV810 Single/2 Way 500W

ZV900 Power Supply 1000W 6A 5A 3 to 200W LED 3 to 200W

ZV700B Single/2 Way 400W

See pages 30 – 31 for Product Information.

Switch Type

Single or Double Gang

Filament Load

40W min. up to max. Resistive (max.) Inductive (max.) LED Low Energy Low Voltage Fluorescent (max.)

LEDPROSLB LEDPROSLWH •

LEDPRORFKB LEDPRORFKWH •

LEDPROPCB LEDPROPCWH •

LEDPRO10B

LEDPRO10WH

LEDPRO20B

LEDPRO20WH

LEDPRO30B

LEDPRO30WH

LEDPRO50B

LEDPRO50WH

Operating Voltage

230V AC

• 10 650

• 10 750

• 20 1400

• 20 1500

• 30 2050

• 30 2100

• 50 3500

• 50 3600

Output Load Capability

20W 11 to 150W 20 to 200W 18 to 76W • (Optional)

20W Up to 85W with adaptor FLA01 *

20W Up to 85W with adaptor FLA01 *

20W 40 to 150W 15 to 150W* 18 to 150W

Maximum Light Load

Internal (W)

LED Brightness

Minimum Lumen

Optional Modes

Dusk to Dawn/Permanent ON/Test

• IP55 12 180° 3 18 2 to 1000

• IP55 12 180° 3 18 2 to 1000

• IP55

• • • •

• • • •

76W

Weatherproof Rating

IP65

Light Level Sensing Light ON Time

• • •

Detection Range

Metres (max.)

• •

Adjustable

Angle of Detection Light ON Time after last

Weatherproof Rating

• 2x 1mm Solid Core Cable, 2x 1mm Twin and Earth Flat Cable <1W 110mm •

IP20

Seconds (min.)

Cable Provision Power Consumption Fixing Hole Centres Operating Temperature Concealed Front Panel EC Directives

Detection (Adjustable)

Minutes (max.)

Adjustable Light Level Control (LUX) Remote Control

LEDPROFOB

• • 114x78x127

0° to 40°C

EC Directives

Conforms to Latest Directives

• 155x117x60

• 155x117x60

• 205x158x63

• 205x158x63

• 265x197x66

• 265x197x66

• 335x252x69

• 335x252x69

• 91x78x73

• 114x78x127

Dimensions (mm)

Height x Width x Depth

• 115 86 x 86 x 50

• 122 86 x 86 x 22

• 122 86 x 86 x 22

• 135 86 x 86 x 38

Conforms to Latest Directives Height (Open)

Dimensions (mm)

28 x 119 x 42

Height (Closed) x Width x Depth

Note: Cannot be used with dimmer or other electronic switches in two way switching systems or replace an intermediate switch in three or more way switching systems. Unsuitable for use with discharge and LED lighting. These products need to be permanently powered which is achieved through the switched Live. As such, some LED and CFL lamps may glow or ash whilst this product is in the ‘OFF’ position. This glow/ ash can be eliminated by adding the Timeguard ZV900 Automatic Switch Load Controller to the circuit. The LED switching capabilities of this product can be increased up to 200W by the addition of the Timeguard ZV900 Automatic Switch Load Controller. The ZV900 is sold separately. *ZF810 Philips or Osram bulbs only. ZV900: Speci cally designed to operate with Timeguard ZV700, ZV700B, ZV210, ZV215, DS1, ZV810, NMT01, NTM02, NTT01, NTT02, NTT03, NTT04, NTT05, NTT06, NTT07 and NTT08 when used with LED or CFL lighting.

sales office 020 8452 1112

fax 020 8450 0635

email csc @ timeguard.com

visit our website timeguard.com

Made with FlippingBook - Online Brochure Maker