TimeGuard Product Catalogue
52
53
Safet y
Safet y
Tr ipf as t RCD Protec t ion
Tr ipf as t RCD Protec t ion
TFA01W
TFP04ML
TFP10WL
TFA05W
TFP08ML
Single socket RCD circuit breaker simply replaces an existing single socket outlet. The contacts break when power supply is temporarily lost. TFA01W Tripfast RCD Single White Socket – Active ■ Protects appliances from possible fire hazard. ■ Manual reset. ■ Extra fast action – trips out within 40 milliseconds (BS7288). ■ Automatically disconnects both Live and Neutral connections leaving Earth connection intact. ■ Trips out when the power supply is temporarily lost. A safety must for machine tool applications.
TFA03M Tripfast RCD Single Metal Socket – Active
RCD Fused Connection Unit gives additional protection against electric shocks and fire risk. The unit will remain latched if the power supply is tripped. TFP10WL Tripfast RCD White Fused Connection Unit – Passive ■ Provides additional protection against the dangers of electrocution. ■ Eliminates the need for plug-in residual current circuit breakers. ■ Protects appliances from possible fire hazard. ■ Extra fast action – trips out within 40 milliseconds (BS7288). ■ Latching for continuous operation after supply interruption. ■ Disconnects both Live and Neutral connections leaving Earth connection intact. ■ Test button for safety checks. ■ Complies with BS7288.
Double socket RCD circuit breaker has all the features and benefits of the TFA01W but provides two switched socket outlets. TFA05W Tripfast RCD Double White Socket – Active ■ Protects appliances from possible fire hazard. ■ Manual reset. ■ Extra fast action – trips out within 40 milliseconds (BS7288). ■ Automatically disconnects both Live and Neutral connections leaving Earth connection intact. ■ Trips out when the power supply is temporarily lost. A safety must for machine tool applications.
Double socket RCD metal circuit breaker has all the features and benefits of the TFA03M but provides two switched socket outlets. TFA07M Tripfast RCD Double Metal Socket – Active
Shares all the features and benefits of the TFA01W and is a single socket metal RCD circuit breaker. Its strong metal construction is ideal for use in factories and other industrial environments where protection against shock and fire hazard is essential.
■ Supplied with a 40mm BS metal surface wall box.
TFP08ML Passive Version
■ Supplied with a 40mm BS metal surface wall box.
Shares the same specifications as the TFA07M but is latching (power is immediately restored to the appliance/equipment at the end of a power failure).
■ Test button for safety checks. ■ Still protects with lost Neutral. ■ Still protects with pulsating DC earth fault currents. ■ Complies with BS7288 and BS1363.
TFP04ML Passive Version
■ Supplied with a 40mm BS metal surface wall box.
Shares the same specifications as the TFA03M but is latching (power is immediately restored to the appliance/equipment at the end of a power failure).
■ Test button for safety checks. ■ Still protects with lost Neutral. ■ Still protects with pulsating DC earth fault currents. ■ Complies with BS7288 and BS1363.
TFP06WL Passive Version
Take advantage of our amazing price deals on a range backed by Timeguard’s 3 year guarantee. For quantity and pricing deals contact your local sales manager or the sales office direct number 020 8452 1112.
■ Supplied with a 40mm BS metal surface wall box.
Shares all the features and benefits of the TFA05W with the addition of latching (power is immediately restored to the appliance/equipment at the end of a power failure) and replaces an existing double socket unit.
TFP02WL Passive Version
■ Remains latched when the power supply is temporarily lost.
All these products carry a 3 year guarantee.
Shares all the features and benefits of the TFA01W but it will remain latched if the supply is temporarily lost.
See page 88 for product specifications.
RCD plug-in adaptor detects dangerous earth leakages and automatically disconnects both live and neutral connections (double pole) leaving the earth connection intact. CB008 Safety Breaker RCD Adaptor
■ Provides additional protection from electric shocks. ■ Extra fast action – trips out within 40 milliseconds (BS7071). ■ Trips out when the power supply is temporarily lost. A safety must for all power tools, lawnmower and hedge trimmers. ■ Automatically disconnects both Live and Neutral connections leaving Earth connection intact.
Quality and Quantity Timeguard’s bulk purchase range of ‘Tripfast’ RCDs. Choose and order from our range of single & twin RCD socket outlets fully conforming to BS7288 and BS1363 and supplied in 6 pack display cartons.
CB008
sales office 020 8452 1112
fax 020 8450 0635
email csc @ timeguard.com
visit our website timeguard.com
Made with FlippingBook - Online Brochure Maker