Scame Industrial Connectors Catalogue
ISOLATORS-TP Series
8
69
50
800
160
160
160
160
160
160
160
160
125
100
125
3000
160A
10-70
10-70
8
55
50
800
125
125
125
125
125
125
125
125
125
100
125
3000
125A
10-70
10-70
8
80
80
80
80
40
63
32
46
30
800
100
100
100
100
1500
100A
10-50
10-50
8
80
80
40
80
63
32
37
50
80
800
160
160
160
160
80A
1500
10-50
10-50
8
63
63
63
63
63
63
40
63
63
32
35
50
63
800
63A
1500
10-50
10-50
8
40
40
40
40
40
40
40
40
40
25
50
40
800
40A
18.5
4-25
4-25
1100
8
32
32
32
32
32
32
32
32
32
25
15
50
32
800
32A
4-25
4-25
1100
8
25
25
25
25
25
25
25
25
25
25
11
50
25
800
25A
4-25
4-25
1100
8
16
16
16
16
16
16
16
16
16
16
50
16
7.5
800
16A
4-25
4-25
1100
mm 2
mm 2
A
A
A
A
A
A
A
A
A
A
A
A
kV
kW
VAC
KAeff
Switching of motor loads or other highly inductive loads 500V (3 phase / 3 pole) 690V AC23A Rated operational power 415V Rated short time withstand current Icw (1s) Conditional short circuit current Ip Rated operational current – Ie
TECHNICAL DATA SWITCH DISCONNECTORS 6 AND 8 POLES Rated insulation voltage Ui Rated impulse withstand voltage Uimp Thermal current Ith/Ithe AC21A 415V Resistive loads, including moderate overloads 500V 690V AC22A 415V Mixed resistive and inductive loads, 500V including moderate overloads 690V AC23A 415V
4P SWITCH LINKING FOR DC APPLICATION
Associate fuse size for conditional short circuit current - Type gG Flexible wire Rigid wire
-
-
-
-
8
69
50
800
160
160
160
160
160
160
160
160
125
100
125
3000
160A
10-70
10-70
4
6
6
40
40
25
10
40
250
480
40A
-
-
-
-
8
55
50
800
125
125
125
125
125
125
125
125
125
100
125
3000
125A
10-70
10-70
-
-
-
-
-
-
-
8
46
30
800
100
100
100
100
100
100
100
100
1500
100A
10-50
10-50
4
6
6
32
32
20
10
32
250
480
32A
-
-
4
86
80
80
80
80
80
80
67
67
38
37
55
32
10
80
690
80A
1500
10-35
10-35
-
-
4
63
63
63
63
63
63
63
63
40
30
33
40
25
10
63
690
63A
1500
10-35
10-35
4
6
6
20
20
16
10
20
250
480
20A
4
10
40
40
40
32
32
40
32
32
35
25
25
20
400
690
40A
18.5
28.5
32(*)
10(*)
1.5-10
1.5-16
4
10
32
40
32
32
32
32
32
32
32
25
25
15
20
400
690
32A
mm 2
mm 2
28.5
32(*)
10(*)
1.5-10
1.5-16
A
A
A
A
A
kV
VAC
kAeff
-
4
9
10
20
30
20
20
20
20
20
20
20
20
20
12
400
690
20A
25(*)
10(*)
1.5-10
1.5-16
mm 2
mm 2
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
kV
kW
VAC
KAeff
250V
250V
Squirrel-cage motor: starting, switching off motor during running (3 phase / 3 pole) 690V DC22A 250V Mixed resistive and inductive loads, including moderate overloads 600V Rated short time withstand current Icw (1s) Conditional short circuit current Ip
Rated impulse withstand voltage Uimp Thermal current Ith/Ithe AC21A 415V
Resistive loads, including moderate overloads 500V 690V AC22A 415V
Mixed resistive and inductive loads, including moderate overloads 500V 690V AC23A 415V
Switching of motor loads or other highly inductive loads (3 phase / 3 pole) 500V 690V AC23A Rated operational power 415V AC3 415V
TECHNICAL DATA SWITCH DISCONNECTORS 1 POLES Rated insulation voltage Ui Rated impulse withstand voltage Uimp Thermal current Ith/Ithe AC22A Rated short time withstand current Icw (1s) Conditional short circuit current Ip Rated operational current – Ie
Rated insulation voltage Ui
Mixed resistive and inductive loads, including moderate overloads AC23A Switching of motor loads or other highly inductive loads (3 phase / 3 pole)
TECHNICAL DATA SWITCH DISCONNECTORS 2P, 3P, 3P+N, 4P
Rated operational current – Ie
Associate fuse size for conditional short circuit current - Type gG Flexible wire Rigid wire
Associate fuse size for conditional short circuit current - Type gG Flexible wire Rigid wire (*) Only 4P with 2+2 poles in series
ISOLATORS-TP Series
Made with FlippingBook - professional solution for displaying marketing and sales documents online