Scame Industrial Connectors Catalogue
ISOLATORS-HR Series
-
1A
590.PL0060xx 10A 16A
-
1A
590.PL005 10A
16A
6A
590.PL00400x 16A 16A
4.5A
400V
250V
400V
250V
AUXILIARY CONTACTS
Rated thermal current
Rated operational current AC15
Break before main contacts switches.
-
-
-
-
12
53
30
400
800
400
630
26.5
1000
1600
1600
1250
1600
1250
1250
6300
5040
1600 (*)
2x (80x102)
1600A(*)
-
12
53
30
800
400
630
100
100
26.5
1000
1250
1250
1250
1250
1250
1250
1250
1250
6300
5040
1000
1250A
2x (50x8)
-
12
53
30
90
800
400
525
100
26.5
1000
1000
1000
1000
1000
1000
1000
1000
1000
6300
5040
1000
1000A
2x (50x6)
12
53
30
70
800
800
800
800
800
800
800
800
800
400
420
800
100
26.5
1000
6300
5040
800A
2x240
2x (50x5)
12
53
30
50
40
630
630
630
630
630
630
630
630
500
400
330
630
26.5
1000
6300
5040
630A
2x185
2x (32x6)
12
13
26
26
50
30
500
500
500
500
500
400
400
500
315
250
210
400
1000
4000
3200
500A
2x150
2x (25x4)
12
13
26
26
50
30
400
400
400
400
400
400
400
400
315
250
200
400
1000
4000
3200
400A
2x150
2x (25x4)
12
13
26
26
50
25
315
315
315
315
315
315
315
315
250
200
165
315
185
1000
3150
2520
315A
2x (25x4)
8
12
16
50
25
250
250
250
250
250
250
250
250
200
160
130
250
120
13.5
20x5
1000
2500
2000
250A
8
12
16
50
20
200
200
200
200
200
200
200
200
125
160
105
200
120
13.5
20x5
1000
2000
1600
200A
8
12
85
16
16
160
160
160
160
160
160
160
160
125
100
160
100
120
13.5
20x5
1000
1600
1280
160A
mm 2
(V)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
kW
mm
(kV)
(kA)
(kA)
(kA)
(kA)
(kA)
Switching of motor loads or other highly 500V inductive loads (3 phase / 3 pole) 690V AC23A Rated operational power 415V Rated making capacity 415V AC23 Rated breaking capacity 415V AC23
Mixed resistive and inductive loads, 500V including moderate overloads 690V AC23A 415V
Rated impulse withstand voltage Uimp Thermal current Ith/Ithe AC21A 415V
Resistive loads, including 500V moderate overloads 690V AC22A 415V
current Short circuit withstand current 0.25 sec Short circuit making capacity 415V Back up fuse R.M.S value Peak value Cable section
Rated insulation voltage Ui
Bars dimension
Rated operational current – Ie TECHNICAL DATA HIGH RATING SWITCH DISCONNECTORS 3P AND 3P+N
Short circuit withstand current 1sec
Rated fuse short-circuit
(*) Neutral pole 1250A. Full current neutral pole available on request.
ISOLATORS-HR Series
Made with FlippingBook - professional solution for displaying marketing and sales documents online