Scame Industrial Connectors Catalogue

ISOLATORS-HR Series

-

1A

590.PL0060xx 10A 16A

-

1A

590.PL005 10A

16A

6A

590.PL00400x 16A 16A

4.5A

400V

250V

400V

250V

AUXILIARY CONTACTS

Rated thermal current

Rated operational current AC15

Break before main contacts switches.

-

-

-

-

12

53

30

400

800

400

630

26.5

1000

1600

1600

1250

1600

1250

1250

6300

5040

1600 (*)

2x (80x102)

1600A(*)

-

12

53

30

800

400

630

100

100

26.5

1000

1250

1250

1250

1250

1250

1250

1250

1250

6300

5040

1000

1250A

2x (50x8)

-

12

53

30

90

800

400

525

100

26.5

1000

1000

1000

1000

1000

1000

1000

1000

1000

6300

5040

1000

1000A

2x (50x6)

12

53

30

70

800

800

800

800

800

800

800

800

800

400

420

800

100

26.5

1000

6300

5040

800A

2x240

2x (50x5)

12

53

30

50

40

630

630

630

630

630

630

630

630

500

400

330

630

26.5

1000

6300

5040

630A

2x185

2x (32x6)

12

13

26

26

50

30

500

500

500

500

500

400

400

500

315

250

210

400

1000

4000

3200

500A

2x150

2x (25x4)

12

13

26

26

50

30

400

400

400

400

400

400

400

400

315

250

200

400

1000

4000

3200

400A

2x150

2x (25x4)

12

13

26

26

50

25

315

315

315

315

315

315

315

315

250

200

165

315

185

1000

3150

2520

315A

2x (25x4)

8

12

16

50

25

250

250

250

250

250

250

250

250

200

160

130

250

120

13.5

20x5

1000

2500

2000

250A

8

12

16

50

20

200

200

200

200

200

200

200

200

125

160

105

200

120

13.5

20x5

1000

2000

1600

200A

8

12

85

16

16

160

160

160

160

160

160

160

160

125

100

160

100

120

13.5

20x5

1000

1600

1280

160A

mm 2

(V)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

(A)

kW

mm

(kV)

(kA)

(kA)

(kA)

(kA)

(kA)

Switching of motor loads or other highly 500V inductive loads (3 phase / 3 pole) 690V AC23A Rated operational power 415V Rated making capacity 415V AC23 Rated breaking capacity 415V AC23

Mixed resistive and inductive loads, 500V including moderate overloads 690V AC23A 415V

Rated impulse withstand voltage Uimp Thermal current Ith/Ithe AC21A 415V

Resistive loads, including 500V moderate overloads 690V AC22A 415V

current Short circuit withstand current 0.25 sec Short circuit making capacity 415V Back up fuse R.M.S value Peak value Cable section

Rated insulation voltage Ui

Bars dimension

Rated operational current – Ie TECHNICAL DATA HIGH RATING SWITCH DISCONNECTORS 3P AND 3P+N

Short circuit withstand current 1sec

Rated fuse short-circuit

(*) Neutral pole 1250A. Full current neutral pole available on request.

ISOLATORS-HR Series

Made with FlippingBook - professional solution for displaying marketing and sales documents online