Scame Industrial Connectors Catalogue
COMMAND Series
-
12
50
630
630
630
630
630
630
630
630
500
400
630
630
630
630
630
630
400
630
YF1 KF1 KF2 KF3 KF4 KF5
1000
1500
6300
5040
630A
2x185
2x40x6
DIN/BS
-
12
50
400
400
400
400
400
400
400
400
315
250
400
400
400
400
400
400
250
400
240
32x5
1000
1500
4000
3200
400A
DIN/BS
-
12
50
315
315
315
315
315
315
315
315
250
200
315
315
315
315
315
315
250
315
240
32x5
1000
1500
3150
2520
315A
DIN/BS
-
-
-
12
50
250
250
250
250
250
250
250
250
200
160
250
250
250
250
160
250
120
25x4
1000
1500
2500
2000
250A
DIN/BS
-
-
-
12
50
200
200
200
200
200
200
200
200
160
125
200
200
200
200
160
200
120
25x4
1000
1500
2000
1600
200A
DIN/BS
-
-
12
50
70
160
160
160
160
160
160
160
160
125
100
160
160
160
160
160
160
160
16x4
1000
1500
1600
1280
160A
DIN/BS
-
-
12
80
50
70
125
125
125
125
125
125
125
125
100
125
125
125
125
125
125
125
16x4
1000
1500
1250
1000
125A
DIN/BS
-
-
12
80
63
50
70
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
800
16x4
1000
1500
1000
100A
DIN/BS
-
-
-
-
-
8
80
80
80
80
80
80
80
80
63
45
80
80
50
80
25
100
800
640
80A
12x3
1000
1500
DIN/BS
-
-
-
-
-
8
63
63
63
63
63
63
63
63
45
32
63
63
50
63
25
100
630
504
63A
12x3
1000
1500
DIN/BS
-
-
-
-
-
-
-
-
-
-
-
-
-
-
4
32
32
32
25
32
32
10
32
gG
690
400
320
32A
16-8
1,5-10
-
-
-
-
-
-
-
-
-
-
-
-
-
-
4
25
25
30
16
25
20
10
16
gG
690
400
160
16A
16-8
1,5-10
mm 2
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
kV
mm
VAC
VDC
AWG
KAeff
Resistive loads, including moderate overloads 500V 690V AC22A 400V
Mixed resistive and inductive loads, 500V including moderate overloads 690V AC23A 400V
Rated impulse withstand voltage Uimp Thermal current Ith/Ithe AC21A 400V
Switching of motor loads or other highly inductive loads 500V (3 phase / 3 pole) 690V DC21A 220V Resistive loads, 400V including moderate overloads 600V DC22A 220V
Mixed resistive and inductive loads, 400V including moderate overloads 600V DC23A 220V
Switching of highly inductive loads (e.g. series motors) 400V Conditional short circuit current Associate fuse size for conditional short circuit current Fuse type
Rated insulation voltage Ui
Short circuit protection
Switch size Rated current In TECHNICAL CHARACTERISTICS 2P,3P, 3P+N
Rated operational current – Ie
Rated making capacity at 420V c.a. cos 0,35 (0,45°) Rated making capacity at 420V c.a. cos 0,35 (0,45°) Flexible wire Bars dimension
3P-3P+N (63A-100A-125A-160A- 200A-250A-315A-400A-630A)
Rated current: 16A-32A-63A-100A-125A-160A- 200A-250A-315A-400A-630A Protection degree: IP65 (front operator) Operating ambient
VERSIONS TECHNICAL CHARACTERISTICS Polarity: 2P-3P-3P+N (16A-32A) Switch size YF1
temperature according to the reference standard: -25°C +40°C Max operating
ambient temperature: +60°C
EN 60947-3
and fuse-combination unit.
Low voltage switchgear and controlgear. Part 3: switches, disconnectors, switch-disconnectors
REFERENCE STANDARDS
3P+N with late break early make neutral pole. Front operators box version equipped with door locking in ON position. Padlockable handle.
Box version (B) Base mounting DIN rail fixing
Switch size KF1 Box version (B) Base mounting screws fixing Switch size KF2 Box version (B)
Base mounting screws fixing Switch size KF3 Box version (B)
Base mounting screws fixing Switch size KF4 Box version (B)
Base mounting screws fixing Switch size KF5 Box version (B)
Base mounting screws fixing
SWITCH DISCONNECTORS WITH FUSES - 16A-630A
COMMAND Series
Made with FlippingBook - professional solution for displaying marketing and sales documents online