Scame Industrial Connectors Catalogue

COMMAND Series

-

12

50

630

630

630

630

630

630

630

630

500

400

630

630

630

630

630

630

400

630

YF1 KF1 KF2 KF3 KF4 KF5

1000

1500

6300

5040

630A

2x185

2x40x6

DIN/BS

-

12

50

400

400

400

400

400

400

400

400

315

250

400

400

400

400

400

400

250

400

240

32x5

1000

1500

4000

3200

400A

DIN/BS

-

12

50

315

315

315

315

315

315

315

315

250

200

315

315

315

315

315

315

250

315

240

32x5

1000

1500

3150

2520

315A

DIN/BS

-

-

-

12

50

250

250

250

250

250

250

250

250

200

160

250

250

250

250

160

250

120

25x4

1000

1500

2500

2000

250A

DIN/BS

-

-

-

12

50

200

200

200

200

200

200

200

200

160

125

200

200

200

200

160

200

120

25x4

1000

1500

2000

1600

200A

DIN/BS

-

-

12

50

70

160

160

160

160

160

160

160

160

125

100

160

160

160

160

160

160

160

16x4

1000

1500

1600

1280

160A

DIN/BS

-

-

12

80

50

70

125

125

125

125

125

125

125

125

100

125

125

125

125

125

125

125

16x4

1000

1500

1250

1000

125A

DIN/BS

-

-

12

80

63

50

70

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

800

16x4

1000

1500

1000

100A

DIN/BS

-

-

-

-

-

8

80

80

80

80

80

80

80

80

63

45

80

80

50

80

25

100

800

640

80A

12x3

1000

1500

DIN/BS

-

-

-

-

-

8

63

63

63

63

63

63

63

63

45

32

63

63

50

63

25

100

630

504

63A

12x3

1000

1500

DIN/BS

-

-

-

-

-

-

-

-

-

-

-

-

-

-

4

32

32

32

25

32

32

10

32

gG

690

400

320

32A

16-8

1,5-10

-

-

-

-

-

-

-

-

-

-

-

-

-

-

4

25

25

30

16

25

20

10

16

gG

690

400

160

16A

16-8

1,5-10

mm 2

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

kV

mm

VAC

VDC

AWG

KAeff

Resistive loads, including moderate overloads 500V 690V AC22A 400V

Mixed resistive and inductive loads, 500V including moderate overloads 690V AC23A 400V

Rated impulse withstand voltage Uimp Thermal current Ith/Ithe AC21A 400V

Switching of motor loads or other highly inductive loads 500V (3 phase / 3 pole) 690V DC21A 220V Resistive loads, 400V including moderate overloads 600V DC22A 220V

Mixed resistive and inductive loads, 400V including moderate overloads 600V DC23A 220V

Switching of highly inductive loads (e.g. series motors) 400V Conditional short circuit current Associate fuse size for conditional short circuit current Fuse type

Rated insulation voltage Ui

Short circuit protection

Switch size Rated current In TECHNICAL CHARACTERISTICS 2P,3P, 3P+N

Rated operational current – Ie

Rated making capacity at 420V c.a. cos 0,35 (0,45°) Rated making capacity at 420V c.a. cos 0,35 (0,45°) Flexible wire Bars dimension

3P-3P+N (63A-100A-125A-160A- 200A-250A-315A-400A-630A)

Rated current: 16A-32A-63A-100A-125A-160A- 200A-250A-315A-400A-630A Protection degree: IP65 (front operator) Operating ambient

VERSIONS TECHNICAL CHARACTERISTICS Polarity: 2P-3P-3P+N (16A-32A) Switch size YF1

temperature according to the reference standard: -25°C +40°C Max operating

ambient temperature: +60°C

EN 60947-3

and fuse-combination unit.

Low voltage switchgear and controlgear. Part 3: switches, disconnectors, switch-disconnectors

REFERENCE STANDARDS

3P+N with late break early make neutral pole. Front operators box version equipped with door locking in ON position. Padlockable handle.

Box version (B) Base mounting DIN rail fixing

Switch size KF1 Box version (B) Base mounting screws fixing Switch size KF2 Box version (B)

Base mounting screws fixing Switch size KF3 Box version (B)

Base mounting screws fixing Switch size KF4 Box version (B)

Base mounting screws fixing Switch size KF5 Box version (B)

Base mounting screws fixing

SWITCH DISCONNECTORS WITH FUSES - 16A-630A

COMMAND Series

Made with FlippingBook - professional solution for displaying marketing and sales documents online