Malmbergs Lighting Brochure 2023
Ceiling/Wall Luminaires, 230V
Master/Slave The communication between master and slave unit is wireless with RF signal. Regardless of which master luminaire that detects movement, all slave units in the same group lights up. It is also possible to create a group which only consists of master luminaires.
HF Sensor and Orientation Light The HF sensor is mounted hidden beneath the diffuser. The sensor responds to any movement, regardless of the heat fluctuations around the sensor. As soon as movement is detected, the light turns on 100%. When there is no motion in the detection area the light goes down to orientation light or is completely turned off after the preset time setting. Adjustable setting of detection area, stand-by period (orientation light), stand-by dimming level and lux setting. The lux sensor can be disconnected so that the luminaire reacts to movement only.
99 751 01
99 751 69, 72
Order code
1-6 m, disabled 1-6 m
Range (radius):
Master
Slave
Master
5 sec - 10 min.
5 sec - 30 min.
Hold time to orientation light:
, disabled
Stand-by period (orientation light): 10 sec – 8 Stand-by dimming level:
10-30% 10-50%
2-50 Lux, disabled
Lux setting:
30-150° 5.8GHz
Detection area:
Frequency:
Emergency Light The integrated emergency light inverter detects when there is a power failure and switches to battery power. In emergency light mode the light drops to 260lm/3W. Suitable for stairwells or similar where you do not want it to become completely dark. The luminaire is provided with charging indicator/test button and auto test. With maintained and non maintained operation. Emergency light: 3W LED, 260 lm. Backup time: 3 hrs. Battery: Incl. Ni-MH battery 7.2V 1.8Ah. Ambient temperature: 0ºC to +40ºC.
10%
100%
100%
100%
100%
120°
120°
120°
H (m)
Lux
Ø (m)
H (m)
Lux
Ø (m)
H (m)
Lux
Ø (m)
82.43
5.68
259.9
2.76
223.3
2.75
2
1
1
20.61
11.36
2
2
64.98
5.52
55.79
5.50
4
13.19
14.20
5
3
3
28.88
8.29
24.79
8.25
4
4
16.24
11.05
13.95
11.00
8
5.15
22.72
10
5
5
3.30
28.40
10.40
13.81
8.93
13.75
Ø
Ø
Ø
99 751 00-01: Spectrum chart
99 751 70: Spectrum chart
99 751 71: Spectrum chart
180
180
180
-165
-165
-165
165
165
165
-150
-150
-150
150
150
150
-135
-135
-135
135
135
135
-120
-120
-120
120
120
120
-105
-105
-105
105
105
105
-90
-90
-90
90
90
90
70
60
50
-75
-75
75
75
-75
75
140
120
100
210
180
150
-60
-60
-60
60
60
60
280
240
200
-45
-45
-45
45
45
45
350
300
250
-30
-30
-30
30
30
30
C90/270 C0/180
C90/270 C0/180
C90/270 C0/180
-15
-15
15
15
-15
15
(cd)
(cd)
(cd)
0
0
0
999 751 70: Photometric chart
99 751 00-01: Photometric chart
99 751 71: Photometric chart
120°
120°
H (m)
Lux
Ø (m)
H (m)
Lux
Ø (m)
179.4
2.75
263.9
2.69
1
1
2
2
44.86
5.51
65.97
5.39
3
3
19.94
8.26
29.32
5.08
4
4
11.21
11.01
16.49
10.77
5
5
7.18
13.76
10.56
13.46
Ø
Ø
99 751 72: Spectrum chart
99 751 69: Spectrum chart
180
180
-165
-165
165
165
-150
-150
150
150
-135
-135
135
135
-120
-120
120
120
-105
-105
105
105
-90
-90
90
90
60
40
-75
-75
75
75
120
80
180
120
-60
-60
60
60
240
160
-45
-45
45
45
300
200
-30
-30
30
30
C90/270 C0/180
C90/270 C0/180
-15
-15
15
15
(cd)
(cd)
0
0
99 751 69: Photometric chart
99 751 72: Photometric chart
PROFESSIONAL LIGHTING | 115
Made with FlippingBook Digital Publishing Software