Malmbergs Lighting Brochure 2020
Ceiling/Wall Luminaires LED, 230V
HF Sensor and Orientation Light The HF sensor is mounted hidden beneath the diffuser. The sensor responds to any movement, regardless of the heat fluctuations around the sensor. As soon as movement is detected, the light turns on 100%. When there is no motion in the detection area the light goes down to orientation light or is completely turned off after the preset time setting. Adjustable setting of detection area, stand-by period (orientation light), stand-by dimming level and lux setting. The lux sensor can be discon- nected so that the luminaire reacts to movement only. Range (radius): 1-6 m depending on mounting height Hold time to orientation light: 5 sec - 30 mins. Stand-by period (orientation light): disabled, 10 sec - 30 mins, always on Stand-by dimming level: 10-50% Lux setting: 2-50 Lux, disabled Detection area: 30-150° Frequency: 5.8GHz Emergency Light The integrated emergency light inverter detects when there is a power failure and switches to battery power. In emergency light mode the light drops to 260lm/3W. Suitable for stairwells or similar where you do not want it to become completely dark. The luminaire is provided with charging indicator/test button and auto test. With maintained and non- maintained operation. Emergency light: 3W LED, 260 lm. Backup time: 3 hrs. Battery: Incl. Ni-MH battery 7.2V 1.8Ah. Ambient temperature: 0ºC to +40ºC.
Master/Slave The communication between master and slave unit is wireless with RF signal. Regardless of which master luminaire that detects movement, all slave units in the same group lights up. It is also possible to create a group which only consists of master luminaires.
Master
Slave
Master
10%
100%
100%
100%
100%
110°
110°
110°
110°
H (m)
Lux
Ø (m)
H (m)
Lux
Ø (m)
H (m)
Lux
Ø (m)
H (m)
Lux
Ø (m)
579.1
2.83
579.1
2.83
579.1
2.83
579.1
2.83
1
1
1
1
2
2
2
2
144.8
5.65
144.8
5.65
144.8
5.65
144.8
5.65
3
3
3
3
64.35
8.48
64.35
8.48
64.35
8.48
64.35
8.48
4
4
4
4
36.20
11.31
36.20
11.31
36.20
11.31
36.20
11.31
5
5
5
5
23.17
14.13
23.17
14.13
23.17
14.13
23.17
14.13
Ø
Ø
Ø
Ø
99 750 61: Spectrum chart
99 750 63: Spectrum chart
99 750 66-67: Spectrum chart
99 750 69-71: Spectrum chart
110°
110°
110°
110°
H (m)
Lux
Ø (m)
H (m)
Lux
Ø (m)
H (m)
Lux
Ø (m)
H (m)
Lux
Ø (m)
745.7
2.83
745.7
2.83
745.7
2.83
745.7
2.83
1
1
1
1
2
2
2
2
186.4
5.67
186.4
5.67
186.4
5.67
186.4
5.67
3
3
3
3
82.85
8.50
82.85
8.50
82.85
8.50
82.85
8.50
4
4
4
4
46.61
11.34
46.61
11.34
46.61
11.34
46.61
11.34
5
5
5
5
29.83
14.17
29.83
14.17
29.83
14.17
29.83
14.17
Ø
Ø
Ø
Ø
99 750 72: Spectrum chart
99 750 74: Spectrum chart
99 750 77-78: Spectrum chart
99 750 80-82: Spectrum chart
180
180
-165
-165
165
165
180
180
-165
-165
165
165
-150
-150
150
150
-150
-150
150
150
-135
-135
135
135
-135
-135
135
135
-120
-120
120
120
-120
-120
120
120
-105
-105
105
105
-105
-105
105
105
-90
-90
90
90
-90
-90
90
90
120
120
120
120
-75
-75
75
75
240
240
-75
-75
75
75
240
240
360
360
-60
-60
60
60
360
360
-60
-60
60
60
480
480
-45
-45
45
45
480
480
-45
-45
45
45
600
600
-30
-30
30
30
C90/270 C0/180
C90/270 C0/180
600
600
-30
-30
30
30
C90/270 C0/180
C90/270 C0/180
-15
-15
15
15
(cd)
(cd)
0
0
-15
-15
15
15
(cd)
(cd)
0
0
99 750 66-67: Photometric chart
99 750 69-71: Photometric chart
99 750 61: Photometric chart
99 750 63: Photometric chart
180
180
180
180
-165
-165
-165
-165
165
165
165
165
-150
-150
-150
-150
150
150
150
150
-135
-135
-135
-135
135
135
135
135
-120
-120
-120
-120
120
120
120
120
-105
-105
-105
-105
105
105
105
105
-90
-90
-90
-90
90
90
90
90
150
150
150
150
-75
-75
-75
-75
75
75
75
75
300
300
300
300
450
450
450
450
-60
-60
-60
-60
60
60
60
60
600
600
600
600
-45
-45
-45
-45
45
45
45
45
750
750
750
750
-30
-30
-30
-30
30
30
30
30
C90/270 C0/180
C90/270 C0/180
C90/270 C0/180
C90/270 C0/180
-15
-15
-15
-15
15
15
15
15
(cd)
(cd)
(cd)
(cd)
0
0
0
0
99 750 72: Photometric chart
99 750 74: Photometric chart
99 750 77-78: Photometric chart
99 750 80-82: Photometric chart
PROFESSIONAL LIGHTING | 123
Made with FlippingBook Annual report