Lapp Cables 2021 Catalogue

Power and control cables Various applications • Halogen-free ÖLFLEX ®

72 ÖLFLEX ® ACCESSORIES FLEXIMARK ® SILVYN ® SKINTOP ® EPIC ® HITRONIC ® ETHERLINE ® UNITRONIC ® APPENDIX 1123130 1123139 1123140 1123142 1123144 1123146 1123149 1123151 1123153 1123159 1123160 1123161

Article number

Number of cores and mm² per conductor

Outer diameter [mm]

Copper index (kg/km)

Weight (kg/km)

Article number

Number of cores and mm² per conductor

Outer diameter [mm]

Copper index (kg/km)

Weight (kg/km)

34 G 1.5 2 X 2.5 3 G 2.5 4 G 2.5 5 G 2.5 7 G 2.5 12 G 2.5 18 G 2.5 25 G 2.5 3 G 4.0 4 G 4.0 5 G 4.0

19.8

489.6

786 110 137 174 217 283 467 696 969 213 267 331

1123162 1123166 1123167 1123168 1123169 1123172 1123173 1123177 1123178 1123181 1123182 1123185

7 G 4.0 3 G 6.0 4 G 6.0 5 G 6.0 7 G 6.0 4 G 10.0 5 G 10.0 4 G 16.0 5 G 16.0 4 G 25.0 5 G 25.0 4 G 35.0

13.4 11.7 13.0 14.5 16.0 16.2 18.1 18.8 21.2 23.5 26.4 26.6

268.8 172.8 230.4

432 303 388 480 626 601 735 917

7.6 8.3 9.0

48 72 96

288

10.1 11.2 15.1 18.0 21.1

120 168 288 432 600

403.2

384 480

614.4

768 960

1148 1418 1769 1905

9.8

115.2 153.6

10.8 12.1

1200 1344

192

Unless specified otherwise, the shown product values are nominal values. Detailed values (e.g. tolerances) are available upon request. Copper price basis: EUR 150/100 kg. Refer to catalogue appendix T17 for the definition and calculation of copper-related surcharges. Please find our standard lengths at: www.lappkabel.de/en/cable-standardlengths Packaging size: coil ≤ 30 kg or ≤ 250 m, otherwise drum Please specify the preferred type of packaging (e.g. 1 x 500 m drum or 5 x 100 m coils). Photographs and graphics are not to scale and do not represent detailed images of the respective products.

Similar products • ÖLFLEX ® CLASSIC 130 H BK 0,6/1 kV refer to page 76

Accessories • SKINTOP ® ST-HF-M refer to page 687

ÖLFLEX ® CLASSIC 135 CH Screened halogen-free control cable with improved fire characteristics

Info I

• CPR: Article number choice under www.lappkabel.com/cpr • For use within public buildings and industrial plants

Benefits • Easy installation due to flexible design • Space-saving installation due to small cable diameters • Certified for maritime applications Application range • Public buildings like airports or railway stations • Plant engineering Industrial machinery Heating and air-conditioning systems • Particularly where human and animal life as well as valuable property are exposed to high risk of fire hazards • Note: for the use of AWM (Appliance Wiring Material) cables in industrial machinery (USA) according to NFPA 79: please see the catalogue appendix table T29 • In EMC-sensitive environments (electromagnetic compatibility)

Product features • Flame-retardant according to IEC 60332-1-2 (flame spread on a single cable) • No flame-propagation according to IEC 60332-3-22 and IEC 60332-3-24 respectively IEC 60332-3-25 (Flame spread on vertical cable or wire bundle) • Halogen-free according to IEC 60754-1 (amount of halogen acid gas) Corrosiveness of combustion gases according to IEC 60754-2 (degree of acidity) • Low smoke density according to IEC 61034-2 Norm references / Approvals • UL AWM style 21217 • Based on EN 50525-3-11 • Based on EN 50525-2-51 • Germanischer Lloyd (GL) certificate no. TAE00002RK Product Make-up • Fine-wire strand made of bare copper wires • Core insulation: Halogen-free • Cores twisted in layers • Halogen-free plastic foil wrapping • Tinned-copper braiding • Outer sheath: Special halogen-free compound, grey (similar to RAL 7001)

Technical data

Classification ETIM 5/6 ETIM 5.0/6.0 Class-ID: EC000104 ETIM 5.0/6.0 Class-Description: Control cable Core identification code Black with white numbers acc. to VDE 0293-334 Conductor stranding Fine wire according to VDE 0295,

class 5/IEC 60228 class 5 Minimum bending radius

Occasional flexing: 20 x outer diameter Fixed installation: 6 x outer diameter

Nominal voltage U0/U: 300/500 V UL: 600 V Test voltage Core/core: 4000 V

Core/screen: 2000 V Protective conductor G = with GN-YE protective conductor X = without protective conductor Temperature range Occasional flexing: -25°C to +70°C (UL: +75°C) Fixed installation: -40°C to +80°C (UL: +75°C)

For current information see: www.lappgroup.com