Power and control cables Power chain applications • Various applications, certified
ÖLFLEX ® ACCESSORIES FLEXIMARK ® SILVYN ® SKINTOP ® EPIC ® HITRONIC ® ETHERLINE ® UNITRONIC ® APPENDIX
ÖLFLEX ® CHAIN 809 SC CY Highly flexible, screened single core cable with PVC insulation and PVC sheath - certified for North America
Info I
• Basic Line Performance - Moderate travel lengths or acceleration • AWM certification for USA and Canada • EMC compliant copper screening
Benefits • Multi-standard certification reduces part varieties and saves costs • Multifunctional application possibilities • Under consideration of the temperature range also suitable for flexible outdoor use • Copper braiding screens the cable against electromagnetic interference • Certified for the USA and Canada for export-oriented machine, appliance and apparatus manufacturers Application range • In power chains or moving machine parts • For internal wiring of electric and electronic equipment in switch cabinets • Specially designed for power circuits of servomotors driven by frequency converters • This cable can substitute screened multi-core motor cables where space requirements or minimum bending radii cause problems • Test systems in the automotive industry, vehicles and stationary fuel cell systems
Product features • Flammability:
Technical data
Classification ETIM 5/6 ETIM 5.0/6.0 Class-ID: EC000057 ETIM 5.0/6.0 Class-Description: Low voltage power cable Core identification code Black, other colours are available upon request Conductor stranding Fine wire according to VDE 0295 Flexing: up from 10 x outer diameter Fixed installation: 4 x outer diameter Nominal voltage IEC: U 0 /U 600/1000 V UL & CSA: 600 V Bending cycles & operation parameters Class 5/ IEC 60228 Class 5 Minimum bending radius See Selection Table A2-1 in the appendix of our online catalogue Test voltage 4000 V Temperature range Flexing: 0°C to +70°C (UL: +90°C) Fixed installation: -40°C to +70°C (UL: +90°C)
UL/CSA: VW-1, FT1 IEC/EN: 60332-1-2
• Oil-resistant according to DIN EN 50290-2-22 (TM54) • Low-adhesive surface • EMC-compliant Norm references / Approvals • Based on VDE 0250 / 0285
• UL-AWM-Style 10107 cRU AWM II A/B FT1 • UL File No. E63634 • For use in power chains: Please comply with assembly guideline Appendix T3 Product Make-up • Fine-wire, bare copper conductor • Core insulation: PVC • Non-woven wrapping • Tinned-copper braiding • Non-woven wrapping • PVC outer sheath, black (similar RAL 9005)
Article number Conductor cross-section (mm²)
Outer diameter [mm]
Copper index (kg/km)
Weight (kg/km)
ÖLFLEX ® CHAIN 809 SC CY 1062940
6
8.1 9.7
76
126 190 250 351 519 686 885
1062941 1062942 1062943 1062944 1062945 1062946 1062947 1062948 1062949 1062950 1062951 1062952
10 16 25 35 50 70 95
122 180 268 392 544 766
10.6
12
14.8 16.8 18.5 20.9 24.1 26.1 28.4 31.9 33.5
1020 1272 1593 1941 2518 3116
1135 1443 1788 2177 2671 3299
120 150 185 240 300
Unless specified otherwise, the shown product values are nominal values at room temperature. Detailed values (e.g. tolerances) are available upon request. Copper price basis: EUR 150/100 kg. Refer to catalogue appendix T17 for the definition and calculation of copper-related surcharges. Please find our standard lengths at: www.lappkabel.de/en/cable-standardlengths Packaging size: coil ≤ 30 kg or ≤ 250 m, otherwise drum Please specify the preferred type of packaging (e.g. 1 x 500 m drum or 5 x 100 m coils). Photographs and graphics are not to scale and do not represent detailed images of the respective products.
Similar products • ÖLFLEX ® CHAIN 90 CP refer to page 145 • ÖLFLEX ® FD 90 CY refer to page 133
Accessories • SILVYN ® CHAIN cable protection and guiding systems
131
For current information see: www.lappgroup.com