FuseBox Circuit Protection 2019
FuseBox Circuit Protection 2019 brochure featuring a collection of 18th Edition Solutions
18th Edition Solutions CIRCUIT PROTECTION
T2 SURGE PROTECTION CONSUMER UNITS
DESIGN FEATURES Provision for T2 surge protection Earth and neutral terminal bars at the top Removable and raised DIN rail Round knock-outs on all faces Extra height for RCBOs Arctic white finish Tail clamp (to be ordered separately ACCF) Busbar shroud Spirit level Circuit Identification
MAIN SWITCH INCOMER (100A)
PART NUMBER
USABLE WAYS
F1006MX
6 WAY (100A main switch) SPD T2
F1006MX
F1010MX
10 WAY(100A main switch) SPD T2
F1014MX
14 WAY (100A main switch) SPD T2
F1020MX
20 WAY (100A main switch) SPD T2
DUAL RCD
PART NUMBER
USABLE WAYS
F1006DX
6WAY SPD T2 (2 x 80A 30mA RCDs AC)
F1010DX
10WAY SPD T2 (2 x 80A 30mA RCDs AC)
F1010DX
F1010DX100
10WAY SPD T2 (2 x 100A 30mA RCDs TYPE A)
F1016DX
16WAY SPD T2 (2 x 80A 30mA RCDs AC)
CIRCUIT PROTECTION The FuseBox circuit protection range of metal
F1016DX100
16WAY SPD T2 (2 x 100A 30mA RCDs TYPE A)
consumer units and protection devices, offers flexible versatile solutions for 18th Edition electrical installations. Our 18th Edition range has been designed to allow a 2 module SPD to be fitted to the RHS of the incomer without affecting the number of usable ways. If an SPD is not required these additional 2 modules
DUAL RCD (MCB POPULATED)
PART NUMBER
USABLE WAYS
MCBS
can be used for devices such as time clocks, installation contactors or a bell transformer.
10 WAY (6xMCBS) SPD T2 (2x 80A 30mA RCDs AC) 16 WAY (8xMCBs) SPD T2 (2x 80A 30mA RCDs AC)
F110PMX
6A x2, 16A x1, 32A x3
F110PMX
F116PMX
6A x3, 16A x1, 32A x4
The range comprises of 4, 8, 12, 16 and 22 module enclosures in different variations suitable for the majority of applications and installations. These include: Main switch incomer, RCD incomer, Dual RCD, Populated MCB & RCBO and garage unit. THE RANGE
FuseBox SPD consumer unit range is designed to meet the requirements of the 18th Edition wiring regulations. Our Dual RCD consumer units are supplied with 80A 30mA AC type RCDs as standard with 100A Type A version also available. T2 SURGE PROTECTION CONSUMER UNITS
2
3
MAIN SWITCH INCOMER (100A)
PART NUMBER
USABLE WAYS
F1002M
2 WAY (100A main switch)
F1006M
F1006M
6 WAY (100A main switch)
F100GR
F1010M
10 WAY (100A main switch)
F1014M
14 WAY (100A main switch)
GARAGE UNIT
F1020M
20 WAY (100A main switch)
PART NUMBER
USABLE WAYS
F100GR
63A 30mA RCD + 6A & 16A MCBs
RCD INCOMER
F1010M
PART NUMBER
USABLE WAYS
METAL ENCLOSURE
F1002R
2 WAY (63A 30mA)
PART NUMBER
USABLE WAYS
F1004E
F1006R
6 WAY (80A 30mA)
4 MOD ENCLOSURE Earth & neutral terminal bars
F1004E
DUAL RCD
CHANGEOVER SWITCH
PART NUMBER
USABLE WAYS
F1006D80
6 WAY (2x 80A 30mA RCDs AC)
PART NUMBER
USABLE WAYS
F1006D80
F1010D80
10 WAY (2x 80A 30mA RCDs AC)
125A Changeover Switch 1P + N in metal enclosure
SCO125
SCO125
F1016D80
16 WAY (2x 80A 30mA RCDs AC)
125A Changeover Switch and Busbar (DIN rail mounting)
SCO125SWB
SPD T2 (SURGE PROTECTION DEVICE) Suitable for TN, TNC-S, TNC and TT systems. Surge protection device must be installed upstream of an RCD within the installation.
FUSED SWITCH
Supplied with European fuses & fuse holder
PART NUMBER
USABLE WAYS
F1M2SPD
PART NUMBER
DESCRIPTION
80A FUSED SWITCH (inc ME080 fuse and shroud) 100A FUSED SWITCH (inc 63A, 80A100A gG fuses)
FMS080
RETRO FIT T2 (2+0) SPD & 100A main switch in a metal enclosure
F1M2SPD
SF0100
SF0100
T2 SPD (2MODULE) 40kA 275V/Up 1.5kV Supplied with E,N and L cables to retro fit into FuseBox consumer unit
SPD2PT2
SPD2PT2
TAIL CLAMP
FMSO80
PART NUMBER
DESCRIPTION
TAIL CLAMP FOR LIVE AND NEUTRAL UP TO 25mm² (To t FuseBox consumer units on pages 3 and 4)
ACCF
ACCF
Dual RCD FLEX consumer units offer flexible solutions for the majority of electrical installations. The Dual RCD Flex version can be configured with up to 2 unprotected high integrity ways on the main switch. The busbar can be cut to suit the split required ensuring the loads are shared evenly across the 2x 80A 30mA RCDs. DUAL RCD
Our compact metal Garage unit, changeover switch, modular enclosure and fused switch (SF0100) are manufactured from metal and finished in arctic white. Knockouts top and bottom with a padlock facility (padlock not included). PADLOCKABLE ENCLOSURES
FUSED SWITCHES
FMS080 and SF0100 are supplied with European fuses and fuse holders, with final assembly in the UK.
4
5
MCB 6KA 1P BS EN 60898-1
ACCESSORIES
TD1
AMBP
MCB 6kA
PART NUMBER
DESCRIPTION
MODULE
CURRENT
B CURVE
C CURVE
ACCF ABTR AMBM AMBP CPL IT1002 TD1
BELL TRANSFORMER
2
TAIL CLAMP (DOES NOT FIT F1004E) MODULE BLANKS METAL (6)
MT06B101 MT06B061
MT06C061
6
10
MODULE BLANKS ABS (12)
12
MT06B161
MT06C161
16
MCB LOCK + PADLOCK
MT06B201
MT06C201
20
MAIN SWITCH 100A 2P
2
MT06B251
25
IT1002
TIME CLOCK 7DAY 1CH 150H
2
MT06B321
MT06C321
32
MT06B401
40
INSTALLATION CONTACTORS
MT06B501
50
ABTR
MT06B631
63
SUPPLIED WITH 2 x 9mm HEAT DISSIPATION SPACERS (+1)
PART NUMBER INC254 INC202 INC402 INC634
DESCRIPTION
MODULE 18MM
RCBO 6KA (TYPE AC AND TYPE A) BS EN 61009-1
20A 2P N/O 230V
1 (+1)
RCBO
CPL
25A 4P N/O 230V
2 (+1)
40A 2P N/O 230V 63A 4P N/O 230V
3 (+1) 2 (+1)
CURRENT
B CURVE – AC
C CURVE – AC
B CURVE – A RTA061030B RTA060630B RTA061630B RTA062030B
RT061030B RT060630B
RT060630C
6
RT061630C RT061030C
10
COMPRESSION GLANDS IP68
RT061630B
16
RT062030B
RT062030C
20
PART NUMBER G25 G20 G32
DESCRIPTION
INC
RT062530B
25
20mm (10pcs) 25mm (10pcs) 32mm (5pcs)
RT063230B
RT063230C
RTA063230B RTA064030B
32
RT064030B
40
RT065030B
50
GKIT01 G40 GKIT02
40mm (1pc), 32mm (1pc), 25mm (10pcs) 12pcs mixed 40mm (2pcs) insert for 25mm² tails and 16mm² earth 40mm (2pcs), 32mm (2pcs), 25mm (20pcs) 24pcs mixed
G40
RCD 2P (TYPE AC AND TYPE A) BS EN 61008-1
CONTROL STATIONS IP55
TYPE
30mA – AC
30mA – A
100mA – AC
RT0400302 RT0250302
25 40
PART NUMBER
DESCRIPTION
CGSSST CGEMST
EMERGENCY STOP STATION TWIST TO RESET (N/C AUX) START STOP STATION (N/O + N/C AUX)
RT0630302
RTA630302
63
RT0800302
RTA800302
80
RT1001002S RT0801002
80 100
RCD GROUP
CGEMST
CGSSST
RTA100302
TRIPPING CHARACTERISTICS
B CURVE: C CURVE:
Type AC – General purpose RCD for use on AConly Type A – RCD used to detect ACand pulsatingDCcomponents S Type – Time delayed version
3-5In 5-10In
Short Circuit Capacity
6kA
S
Mounting:
35mm DIN rail
6
7