Expert Electrical Product Guide 2022

INDUSTRIAL CONTROLS

Overload Relays Contactors & Overloads

TeSys Model D

TeSys Model K • Class 10A differential Bi-metallic thermal overload relay

Schneider

• Class 10A differential Bi-metallic thermal overload relay

For Use with Contactor LC1

Settings Range Amps

Part No.

Part No. LR2K0303 LR2K0304 LR2K03058 LR2K0306 LR2K0307 LR2K0308 LR2K0310 LR2K0312 LR2K0314 LR2K0316

Settings Range Amps

0.23 ... 0.36 0.36 ... 0.54 0.54 ... 0.8 0.8 ... 1.2 1.2 ... 1.8 1.8 ... 2.6 2.6 ... 65.0 3.7 ... 70.0 5.5 ... 80.0 8.0 ... 104.0

LRD05 LRD06 LRD07 LRD08 LRD10 LRD12 LRD14 LRD16 LRD21 LRD22 LRD32 LRD35 LRD340 LRD350 LRD365 LRD3322 LRD3353 LRD3355 LRD3357 LRD3359 LRD3361 LRD3363 LRD3365

D09 ... D38 D09 ... D38 D09 ... D38 D09 ... D38 D09 ... D38 D09 ... D38 D09 ... D38 D12 ... D38 D18 ... D38 D25 ... D38 D12 ... D38 D32 + D38 D80 + D95 D80 + D95 D80 + D95 D80 + D95 D80 + D95 D80 + D95 D80 + D95 D80 + D95 D40A ... D65A D40A ... D65A D50A ... D65A

0.63 ... 1.0 1.0 ... 1.7 1.6 ... 2.5 2.5 ... 4.0 4.0 ... 6.3 5.5 ... 8.0 7.0 ... 10.0 9.0 ... 13.0 12.0 ... 18.0 16.0 ... 24.0 23.0 ... 32.0 30.0 ... 38.0 30.0 ... 40.0 37.0 ... 50.0 48.0 ... 65.0 17.0 ... 25.0 23.0 ... 32.0 30.0 ... 40.0 37.0 ... 50.0 48.0 ... 65.0 55.0 ... 70.0 63.0 ... 80.0 80.0 ... 104.0

LRD Accessories • Seperate Mounting Base for overload relays

Part No. LAD7B106 LAD73064

Contacts

LRD01 ... LRD35

LRD33**

Overload Relays TeSys Model K Contactors

K-Range Auxillary Blocks

TeSys Model D Contactors • 3 Pole 9-150A/AC3 (Control coils included) • See table below for AC coil or DC coil suffix

• 3 Pole 6-12A/AC3 (Control coils included) • See table below for AC coil or DC coil suffix

Part No.

3Ph/400V (kW)

AC-3 (A)

Auxiliary NO NC

Part No. LA1KN11 LA1KN20 LA1KN22

Contacts 1 NO + 1 NC

LC1D09** LC1D12** LC1D18** LC1D25** LC1D32** LC1D38** LC1D40A LC1D50A LC1D65A LC1D80** LC1D95** LC1D115** LC1D150**

4

9

1 1 1 1 1 1 1 1 1 1 1 1 1

1 1 1 1 1 1 1 1 1 1 1 1 1

2 NO

5.5 7.5

12 18 25 32 38 40 50 65 80 95

2 NO + 2 NC

D-Range Auxillary Blocks

11 15

Part No.

3Ph/400V (kW)

AC-3 (A)

Auxiliary NO NC

18.5 18.5

LC1K0601** LC1K0610** LC1K0901** LC1K0910** LC1K1201** LC1K1210**

2.2 2.2

6 6 9 9

-

1

22 30 37 45 55 75

1

-

4 4

-

1

1

-

5.5 5.5

12 12

-

1

115 150

1

-

Part No. LADN01 LADN10 LADN22 LADN40 LADN04

Contacts

1 NC 1 NO

Coil Voltages - Add the suffix below to the contactor reference to specify control voltage required

Coil Ref (Last 2 Digits)

12

24 B7 BD

42 C7 FD

48 E7

110

230

380

400

2 NO + 2 NC

AC Supply DC Supply

4 NO 4 NC

J7 JD

F7

P7

Q7

V7

341