Entrelec-Terminals-brochure

Selection guide

Selection guide

SWITCH FOR NEUTRAL CIRCUIT

FEED THROUGH

GROUND

DOUBLE DECK

TRIPLE DECK

SENSOR/ ACTUATOR

DISTRIBUTION

HEAVY DUTY SWITCH

Page 15 - 16

Page 12

Page 11

Page 2 to 9

Page 13 - 14

Page 2 to 10

Page 17 - 18

Page 25 to 27

SCREW CLAMP TERMINAL BLOCKS

Page 29

Page 19 to 24

Rated wire size : 0.2 to 2.5 mm² (20 to 12 AWG) Spacing : 6 mm (.238") Current : 22 A

Rated wire size : 0.2 to 4 mm² (22 to 12 AWG) Spacing : 6 mm (.238") Current : 22 to 32 A

Rated wire size : 0.2 to 10 mm² (22 to 8 AWG) Spacing : 5 to 8 mm (.200" to .315") Current : 24 to 41 A

Rated wire size : 0.2 to 120 mm² (22 to 0000 AWG) Spacing : 5 to 26 mm (.200" to 1.02") Short circuit current : 300 to 11400 A/1s

Rated wire size : 0.2 to 50 mm² Spacing : 5 to 16 mm (.200" to .669") Current : 24 to 125 A

Rated wire size : 0.2 to 300 mm² (22 to 350 MCM) Spacing : 5 to 36 mm (.200" to 1.41") Current : 24 to 415 A

Rated wire size : 0.2 to 10 mm² (24 to 8 AWG) Spacing : 5 to 6 mm (.198" to .236") Current : 10 to 20 A

Rated wire size : 0.2 to 120 mm² (18 to 0000 AWG) Spacing : 6 to 50 mm (.236" to 1.97") Current : 30 to 250 A

Page 42

Page 42

Page 43

Page 46

Page 44 - 45

Page 36 to 41

Page 36 to 41

SPRING CLAMP TERMINAL BLOCKS

Rated wire size : 0.12 to 4 mm² (26 to 12 AWG) Spacing : 5 mm (.198") Current : 10 A

Rated wire size : 0.14 to 4 mm² (26 to 12 AWG) Spacing : 5 mm (.198") Current : 20 to 24 A

Rated wire size : 0.14 to 2.5 mm² (26 to 16 AWG) Spacing : 5 mm (.198") Current : 17.5 A

Rated wire size : 0.12 to 4 mm² (26 to 12 AWG) Spacing : 5 mm (.198") Current : 20 A

Rated wire size : 0.12 to 50 mm² (26 to 2 AWG) Spacing : 4 to 16 mm (.158" to .630") Short circuit current : 180 to 4200 A/1s

Rated wire size : 0.12 to 16 mm² Spacing : 5 to 10 mm (.198" to .394") Current : 24 to 57 A

Rated wire size : 0.12 to 50 mm² (26 to 2 AWG) Spacing : 4 to 16 mm (.158" to .630") Current : 18 to 125 A

Page 58

Page 57

SCREW CLAMP - ADO IDC TERMINAL BLOCKS

Page 53 to 56

Page 53 to 56

Rated wire size : 0.2 to 6 mm² (22 to 10 AWG) Spacing : 5 to 8 mm (.198" to .315") Current : 10 to 15 A

Rated wire size : 0.2 to 10 mm² (22 to 10 AWG) Spacing : 6 to 8 mm (.238" to .315") Current : 17.5 to 24 A

Rated wire size : 0.2 to 10 mm² (22 to 8 AWG) Spacing : 5 to 8 mm (.200" to .315") Short circuit current : 120 to 480 A/1s

Rated wire size : 0.2 to 10 mm² (22 to 8 AWG) Spacing : 5 to 8 mm (.198" to .315") Current : 13.5 to 32 A

Page 71

Page 72

Page 70

Page 66 to 69

Page 66 to 69

ADO - ADO IDC TERMINAL BLOCKS

Rated wire size : 0.2 to 2.5 mm² (24 to 14 AWG) Spacing : 5 to 8 mm (.198" to .315") Current : 10 to 15 A

Rated wire size : 0.2 to 1 mm² Spacing : 5 mm (.198") Current : 13.5 A

PLUGGABLE TERMINAL BLOCKS Rated wire size : 0.28 to 1.5 mm² (22 to 16 AWG) Spacing : 6 mm (.238") Current : 17.5 A

Rated wire size : 0.2 to 4 mm² (24 to 12 AWG) Spacing : 5 to 8 mm (.200" to .315") Short circuit current : 120 to 480 A/1s

Rated wire size : 0.2 to 4 mm² (24 to 12 AWG) Spacing : 5 to 8 mm (.198" to .315") Current : 13.5 to 32 A

QUICK-CONNECT TERMINAL BLOCKS

PLUGS

Page 81 - 82

POWER TERMINAL BLOCKS

Page 83 - 84

Page 100

Page 98 - 99

Page 85 - 86

Rated wire size : 2.5 to 300 mm² (1 AWG to 1000 MCM) Spacing : 27 to 55 mm (1.06" to 2.16") Current : 125 to 520 A

Rated wire size : 2.5 to 240 mm² (1 AWG to 500 MCM) Spacing : 27 to 55 mm (1.06" to 2.16") Current : 125 to 353 A

Rated wire size : 0.2 to 4 mm² (24-12 AWG) Spacing : 6 mm (.236") Current : 20 to 35 A

Rated wire size : 0.2 to 4 mm² (24-12 AWG) Spacing : 5.08 mm (.200")

Current : 3 to 24 A

1SNC 160 003 C0205

040206

guideBU_1-2

Gross Automation (877) 268-3700 · www.entrelecsales.com · sales@grossautomation.com