ESP Fire & Security Products

TWO WIRE DETECTORS

TWO WIRE SOUNDERS

MAGDUOSHD

FlexiPoint Detector for Fire Detection

Q 7 modes of fire detection including combined smoke/heat Q Built-in End of Line function Q Self-calibration every 6 hours Q Continuous dust contamination monitoring Q Device wiring base included

MAGDUOSW White

MAGDUOSWSQ White

MAGDUOSRSQ Red

MAGDUOSR Red

Ce i l i ng Sounder for MAGDUO

Wa l l Sounder for MAGDUO

Q Ceiling mount sounder Q Volume level adjustment Q Built-in End of Line function Q Device wiring base included

Q Wall mount white sounder Q Volume level adjustment Q Built-in End of Line function Q Device base included

MAGDUOSHDS

Q 7 modes of fire detection including combined smoke/heat Q Complete with 3 sounder modes Q Built-in End of Line function Q Self-calibration every 6 hours Q Device wiring base included Q Continuous dust contamination monitoring F l ex iPo i nt Detector wi th Sounder for F i re Detect i on

MAGDUOSSLP

MAGDUOSS

Sounder Strobe for MAGDUO - Low Profile Sounder Strobe for MAGDUO - Domed

Q Complete with 3 sounder modes and LED strobe Q Volume level adjustment Q Built-in End of Line function Q Low profile design Q Device wiring base included

Q Complete with 3 sounder modes and LED strobe Q Volume level adjustment Q Built-in End of Line function Q Domed profile design Q Device wiring base included

MAGDUOSHDSS

Q 7 modes of fire detection including combined smoke/heat Q Complete with 3 sounder modes and LED strobe Q Built-in End of Line function Q Self-calibration every 6 hours Q Device wiring base included Q Continuous dust contamination monitoring F l ex iPo i nt Detector wi th Sounder & St robe for F i re Detect i on

Q IP55 Ingress protection Q Volume level adjustment Q Built-in End of Line function Q Device base included MAGDUOSRIP55 Sounder for MAGDUO

Q IP55 Ingress protection Q LED strobe Q Built-in End of Line function Q Device base included St robe for MAGDUO MAGDUOS IP55

7 Modes Of Detection

Smoke 1 - Standard optical with high thermal enhancement Smoke 2 - Standard optical with normal thermal enhancement Smoke 3 - Low sensitivity optical with transient rejection

Heat 1 - Rate of Rise 58°C, general use in normal, stable environments (Class A1) Heat 2 - Low fixed 58°C, Domestic kitchens etc (Class A1) Heat 3 - Hi Fixed 90°C, Commercial kitchens, boiler rooms

Combined - Smoke 2 / Heat 2

124

125

Made with FlippingBook - professional solution for displaying marketing and sales documents online