TWO WIRE FIRE PANELS
TWO WIRE FIRE PANELS
MAGDUO2 Grey
MAGDUO2B Black
MAGDUO4 Grey MAGDUO4B Black 4 Zone Two Wire Fire Panel
Made in UK
Made in UK
EN54
EN54
2 Zone Two Wire Fire Panel
Q Two Wire fire alarm system Q Active end of line monitoring and head removal Q Up to 32 devices per zone (Dependent on Device Loading Unit: DLU) Q 4 line x 20 character LCD display Q Ability to differentiate between smoke detector, heat detector or a manual call point alarms Q Alarm confirmation feature Q Event log storing up to 500 events Q 3 enhanced test modes Q Zone can be configured to day/night detection mode Q Delay programming options Q Certified to EN54 2/4 Standards Q Requires 2 x 12V 3.2Ah batteries (BAT32) Q Optional extended battery box with capacity for 2 x 12V 7.0Ah batteries
Q Two Wire fire alarm system Q Active end of line monitoring and head removal Q Up to 32 devices per zone (Dependent on Device Loading Unit: DLU) Q 4 line x 20 character LCD display Q Ability to differentiate between smoke detector, heat detector or a manual call point alarms Q Alarm confirmation feature Q RS485 connection to up to 8 repeater panels Q Event log storing up to 500 events Q 3 enhanced test modes Q Zone can be configured to day/night detection mode Q Delay programming options Q 4 or 8 zone panel can now be configured to accept conventional devices on zones 5 to 8 with the optional conventional zone card Q Certified to EN54 2/4 Standards Q Requires 2 x 12V 3.2Ah batteries (BAT32) Q Optional extended battery box with capacity for 2 x 12V 7.0Ah batteries
Inputs Max Detectors Per Zone
Inputs Max Detectors Per Zone
Up to 32 Devices (Dependant on Device Loading Units , 160 per Zone)
Up to 32 Devices (Dependant on Device Loading Units , 160 per Zone)
Power Mains Supply
Power Mains Supply
230VAC, +10%, -15%, 50/60Hz 24vDC (Range 21-31vDC) 2 x 12V 3.2Ah S.L.A Battery
230VAC, +10%, -15%, 50/60Hz 24vDC (Range 21-31vDC) 2 x 12V 3.2Ah S.L.A Battery
Operating Voltage
Operating Voltage
Standby Supply
Standby Supply
Outputs Zone
Outputs Zone
Up to 2 (300mA) Up to 2 (250 mA) Up to 2 (250 mA) 24vDC (300mA)
Up to 4 (300mA) Up to 2 (250 mA) Up to 2 (250 mA) 24vDC (300mA)
Monitored Sounder Circuits Monitored Relay Circuits
Monitored Sounder Circuits Monitored Relay Circuits
Auxiliary Output
Auxiliary Output
Environment Working Temperature
Environment Working Temperature
5°C to 40°C
5°C to 40°C
Dimensions
333 x 333 x 99mm
Dimensions
333 x 333 x 99mm
Weight
2.25 Kg
Weight
2.28 Kg
MAGDUOPK (Pack of 2) Two Wire Fire Panel Spare Key
MAGDUOPK (Pack of 2) Two Wire Fire Panel Spare Key
MAGDUOBBB Battery Expansion Box for MAGDUO
MAGDUOPCPS MAGDUO Software
MAGDUOBBB Battery Expansion Box for MAGDUO
MAGDUOPCPS MAGDUO Software