ESP Fire & Security Issue 29
MASTER STATIONS
MASTER STATIONS
Q Large Handset for Full Duplex Audio Q Simple System Interface Q Intergrates; Assist Call, Type A and B Outstations Q Backup Battery (BAT7 Required) Q Fully Compliant to BS5839-9:2021 & BS8300
Q Large Handset for Full Duplex Audio Q Simple System Interface Q Intergrates; Assist Call, Type A and B Outstations Q Backup Battery (BAT7 Required) Q Fully Compliant to BS5839-9:2021 & BS8300
BMSF
Flush Bezel for Master Station
BMSF
Flush Bezel for Master Station
BM2EX
2 Line Expansion Card for Master Station
Inputs Lines
Inputs Lines
2; in 1 of 2-line block
8; in 4 of 2-line block
End of Line
10KΩ
End of Line
10KΩ
Outputs Number of outputs
Outputs Number of outputs
2; Fault & in-use Volt-free relay
2; Fault & in-use Volt-free relay
Type
Type
Contact Rating
30V DC 1A
Contact Rating
30V DC 1A
Power Operating Voltage Battery Type Internal Supply Environment Dimensions
Power Operating Voltage Battery Type Internal Supply Environment Dimensions
230VAC (±10%), 50/60Hz 12V 7Ah SLA (not included)
230VAC (±10%), 50/60Hz 12V 7Ah SLA (not included)
5V, 16V, 27V DC
5V, 16V, 27V DC
B1M2
B1M8
300mm x 350mm x 95mm
300mm x 350mm x 95mm
2 Line Master Station
8 Line Master Station
Weight
5Kg
Weight
5Kg
Q Large Handset for Full Duplex Audio Q Simple System Interface Q Intergrates; Assist Call, Type A and B Outstations Q Backup Battery (BAT7 Required) Q Fully Compliant to BS5839-9:2021 & BS8300
Q 512 Line Capability, requires BMNETEX Expander Every 8 Lines Q 4.3” Full Colour Touchscreen Q Large Handset for Full Duplex Audio Q Simple System Interface Q Integrates; Assist Call, Type A and B Outstation Q Backup Battery Features (Battery not inc.) Q Fully Compliant to BS5839-9:2021 & BS8300
BMSF
Flush Bezel for Master Station
BMSF
Flush Bezel for Master Station
BM2EX
2 Line Expansion Card for Master Station
Inputs Lines
Inputs Lines
4; in 2 of 2-line block
8; in 4 of 2-line block
End of Line
10KΩ
End of Line
10KΩ
Outputs Number of outputs
Outputs Number of outputs
2; Fault & in-use Volt-free relay
2; Fault & in-use Volt-free relay
Type
Type
Contact Rating
30V DC 1A
Contact Rating
30V DC 1A
Power Operating Voltage Battery Type Internal Supply Environment Dimensions
Power Operating Voltage Battery Type Internal Supply Environment Dimensions
230VAC (±10%), 50/60Hz 12V 7Ah SLA (not included)
230VAC (±10%), 50/60Hz 12V 7Ah SLA (not included)
5V, 16V, 27V DC
5V, 16V, 27V DC
B1M4
BMNET
300mm x 350mm x 95mm
300mm x 350mm x 95mm
4 Line Master Station
Touchscreen Master Station
Weight
5Kg
Weight
5Kg
132
133