Click GridPro Brochure

GridPro ® Modules

Technical Specification

J74

J75

TYPICAL 1 WAY SWITCHED CIRCUIT

TYPICAL DOUBLE POLE WIRING DIAGRAM

GM2001BTBK

GM2002BTPW

GM2028BTBK

GM2018BTBK

TYPICAL 2 WAY SWITCHED CIRCUIT

GM2028BT MODULE BACK

GM2001BT MODULE BACK

GM2002BT MODULE BACK

GM2018BT MODULE BACK

20AX Locator Switch Modules (Blue LED) GM2001BTBK

Material Composition

Transparent Trim: Polycarbonate Switch: Urea Rear Housing: Nylon Terminals: Brass Terminal Screws: Steel & Yellow Passivated Contacts: Silver “on-lay” Copper / Brass

20AX 1 Way Locator Black Switch Module With Transparent Surround 20AX 1 Way Locator White Switch Module With Transparent Surround 20AX 2 Way Locator Black Switch Module With Transparent Surround 20AX 2 Way Locator White Switch Module With Transparent Surround 20AX Intermediate Switch Module - Black With Transparent Surround 20AX Intermediate Switch Module - White With Transparent Surround

GM2001BTPW

GM2002BTBK GM2002BTPW GM2028BTBK GM2028BTPW

Voltage

250V~ 50Hz

Current Rating (A)

20AX (suitable for inductive loads)

Terminal Size Torque Value

ø 5mm 1.2Nm

The switch will illuminate when the switch is in the 'OFF' position.

2 x 4mm 2 , 3 x 2.5mm 2 or 1 x 6mm 2

Cable Size (mm²)

20AX Indicator Switch Modules (Blue LED) GM2018BTBK

Back Box Depth (mm)

25mm - 47mm (Deco TM , Deco Plus, Mode TM , Polar TM ) 35mm - 47mm (Define ® , Definity TM )

20AX Double Pole Switch Module - Black With Transparent Surround 20AX Double Pole Switch Module - White With Transparent Surround

Modular

Yes

GM2018BTPW

Warranty (Years)

10 Years

The switch will illuminate when the switch is in the 'ON' position.

Anti Microbial Certified

Yes (Non Ingot Switches Only)

IP Rating

IP20

+5 o C to +40 o C BS EN 60669-1

Operational Temperature

Standards

Additional Information: Ensure that the mains supply is isolated before commencing installation and refer to the circuit diagram supplied with the relevant product.

These products are rated at 20AX; therefore all terminals should not exceed the stated amperage. Bare earth cables must always be covered with appropriate sleeving and wired to the earth terminal.

Standards: BS EN 60669-1 Back Box Depth (mm): 25 (35 Flat Plate) Cable Size (mm²): 3 x 2.5, 2 x 4 Dimensions (mm): 24.5 (W) x 50 (H) x 22.5 (D)

All white moulded accessories are manufactured using Urea Formaldehyde, which has similar inherent properties to antimicrobial additives that inhibit the growth of infectious diseases. All products independently tested have shown to have anti-viral properties against enveloped and non-enveloped viruses. A 99.99% kill off rate across all four types of the strains of bacteria - MRSA, E-Coli, Salmonella, Klebsiella Pneumonia and enveloped viruses and a 92% kill off rate against non-enveloped viruses.

CLICK ® WIRING ACCESSORIES

sales@scolmore.com | Call: 01827 63454 | scolmore.com

Made with FlippingBook Online newsletter creator