ISO 12944-6:2018 – Laboratory Test Requirements Combined specification table for Water Condensation, Neutral Salt Spray, and alternative Cyclic Ageing tests. 1. Water Condensation Test - ISO 12944 6:2018 (using ISO 6270-1 WCT method) The water condensation test assesses the barrier properties, wet adhesion, and resistance to coating degradation under continuously warm and humid conditions. It simulates environments with persistent moisture and condensation. 2. Neutral Salt Spray Test Hours - ISO 12944 6:2018 (using ISO 9227 NSS method) The neutral salt spray test is used in ISO 12944 6 together with the water condensation test to evaluate the corrosion protection performance of paint systems for atmospheric corrosivity categories C2–C5. Purpose of NSS in ISO 12944 6
• Primarily evaluates resistance to underfilm corrosion and performance at defects (scribes) • Complements the condensation test, which focuses more on barrier properties and wet adhesion • Results are assessed using ISO 4628 rating systems
Alternative Cyclic Ageing (ISO 12944-9)
Corrosivity Category (ISO 12944-2)
Durability Range
Water Condensation Test (ISO 6270-1)
Neutral Salt Spray Test (ISO 9227)
Notes
C2
Low
48 h
–
–
Medium
48 h
–
–
High
120 h
–
–
Very High
240 h
480 h
–
C3
Low
48 h
120 h
–
Medium
120 h
240 h
–
High
240 h
480 h
–
Very High
480 h
720 h
–
C4
Low
120 h
240 h
–
Medium
240 h
480 h
–
High
480 h
720 h
–
NSS & condensation are alternatives
Very High
720 h
1,440 h*
Permitted / Preferred
C5
Low
240 h
480 h
–
Medium
480 h
720 h
–
High
720 h
1,440 h*
Permitted / Preferred
NSS/condensation not recommended
Very High
–
–
Required
Immersion environment
Im1
High
1,440 h
–
–
Very High
2,160 h
–
–
Severe offshore exposure
CX – Offshore
–
–
–
Mandatory
* Note: For C4 Very High and C5 High, ISO 12944 6:2018 allows the use of water condensation and NSS only as an alternative. The cyclic ageing test defined in ISO 12944 9 is the preferred and future oriented method. Standard Cyclic Ageing Test (ISO 12944 9 – for reference) One cycle consists of: • 72 h UV exposure with condensation • 72 h neutral salt spray • 24 h at −20 °C Cycles are repeated according to the corrosivity category and durability requirement (e.g. up to 4,200 h / 25 cycles for CX).