Duplexvent FLEXI DV1100 Flexi Line Side Entry - Up to 1100 m 3 /hr air volume

Casing Strength EN 1886, mm/m

Energy Efficiency Eurovent

Key Features ● Extract up to 1000 m³/hr @ 200 Pa

A B C D E F

10 4 0

D3 D2 D1͚

1

● Excellent heat recovery efficiency, up to 95% ● Versatile unit positioning with floor and ceiling suspended mounting options ● Low SFP with energy saving EC fans ● Low noise, refer to NR35 and BB93 standards ● 10 speed digital control with Internet and BMS ● Compliant to BREEAM, Passive House and ErP 2015 regulations ● 2 year warranty +

CERTIFIED COMPONENT Passive House Institute

10 %

10 % 20 %

30 %

40 %

50 %

30

20 %

30 %

40 %

50 % 100 % 90 % 80 % 70 % 60 %

Supply

30

e1 - outdoor air (ODA) e2 - supply air (SUP) Winter Operation*:

100 % 90 % 80 % 70 % 60 %

t [°C]

t [°C]

Description t [ o C] rh [%] e1 Outdoor Air -10.0 90 e2 Supply Air 17.0 12

25

25

i1 - extract air (ETA) i2 - exhaust air (EHA)

i1

i1

20

20

eR=e2

15

50

e2

45

exhaust air

supply air

heat recovery -4,6 kW

15

50

230 V 0,09 kW

230 V 0,09 kW

40

10

35

45

heat recovery -4,6 kW

Exhaust

h [kJ/kg]

500 m 3 /hr 150 Pa 17°C 12%

30 40

17°C 12 %

2°C 100 %

e2

i2

25 35

10

5

B

2 °C 97%

heat recovery 4,6 kW

Description t [ o C] rh [%] i1 Extract Air 22.0 40 i2 Exhaust Air 2.0 100

20

30

h [kJ/kg]

i2

15

0

25

5

-5 heat recovery 4,6 kW

Mi.107.EC1

1200

10

Me.107.EC1

S3.B 84 % 4,6 kW

Performance

5 20

Extract Supply

i2

0 15

0

-10

e1

500 m 3 /hr 150 Pa 22°C 40%

1000

10

-5

-10 °C 90%

0 1 2 3 4 5 6 7 8 9 101112131415 x [g/kg of dry air] -15 5

-5

22° 40 %

-10°C 90 %

e1

i1

0

filtration M5

filtration F7

Exhaust

800

Supply

Sound Power Level Lw (dB) dB (A) 63 125 250 500 1k 2k 4k 8k Outdoor air e1 47 68 57 47 42 35 28 <25 <25 Supply air e2 66 80 74 69 62 60 55 49 47 Extract air i1 45 67 55 46 40 33 26 <25 <25 Exhaust air i2 65 80 7 686058534744 Breakout noise 51 70 55 57 44 40 33 27 25 Sound Pressure Level Ld dB (A) 63 125 250 500 1k 2k 4k 8k To the surrounding 21 49 35 37 <25 <25 <25 <25 <25

extract air

outdoor air

-10

e1

description i1 extract air i2 heat recovery

t [°C] rh [%] 22.0 40 1.5 100

description e1 outdoor air eR heat recovery -5

t [°C] rh [%] -10.0 90 16.7 12

0 1 2 3 4 5 6 7 8 9 101112131415 x [g/kg of dry air] -15

Note: AHU functions diagram. Inlet and outlet location may differ from actual position and port configuration.

600

400

STATIC PRESSURE (Pa)

200

10 %

20 %

30 %

40 %

50 %

30

50 % 100 % 90 % 80 % 70 % 60 %

Supply

10 %

20 %

30 %

40 %

e1 - outdoor air (ODA) e2 - supply air (SUP) Summer Operation*:

30

100 % 90 % 80 % 70 % 60 %

t [°C]

i1 i2 i1 heat recovery i2 -0,6 kW

25

0

25 heat recovery 0,6 kW t [°C]

Description t [ o C] rh [%] e1 Outdoor Air 22.0 35 e2 Supply Air 25.0 29

e1 e2

heat recovery

i1 - extract air (ETA) i2 - exhaust air (EHA)

eR=e2

heat recovery 0,6 kW

0

100

200

300

400

l/sec

-0,6 kW

e1

20

20

Sound pressure level is measured at 3m distance

0

200 400 600 800 1000 1200 1400

m /hr 3

15

50

supply air

exhaust air

45

AIR FLOW

15

50

230 V 0,09 kW

230 V 0,09 kW

40

45

10

35

Exhaust

350 400 250 300 200 150 100 50

h [kJ/kg]

23°C 61%

25°C 29%

500 m 3 /hr 150 Pa 26°C 28%

30 40

e2

i2

10

Ventilation

Supply Air

Extract Air 1000 / 278

B

35

25

23°C 59%

5

Description t [ o C] rh [%] i1 Extract Air 26.0 50 i2 Exhaust Air 23.0 61

h [kJ/kg]

20

30

Maximum air volume @ 200 Pa

m 3 /hr / l/sec 1000 / 278

15

0

25

5

Me.107.EC1

Mi.107.EC1

10

S3.B 80 % -0,6 kW

5 20

-5

15

0

Air volume @ 150 Pa *

0

500 / 139

m 3 /hr / l/sec 500 / 139

-10

10

500 m 3 /hr 150 Pa 26°C 50%

-5

22°C 35%

-5

Nominal voltage

V V

230 230

230 230

5

0 1 2 3 4 5 6 7 8 9 101112131415 x [g/kg of dry air] -15

26°C 50%

22°C 35%

i1

e1

Voltage (at operation point) * Nominal Power (at operation point) *

0

Exhaust

Supply

filtration M5

filtration F7

-10

extract air

outdoor air

-5

description i1 extract air i2 heat recovery

t [°C] rh [%] 26.0 50 22.8 61

description e1 outdoor air eR heat recovery

t [°C] rh [%] 22.0 35 25.2 29

93

87

W

-15

Note: AHU functions diagram. Inlet and outlet location may differ from actual position and port configuration.

0 1 2 3 4 5 6 7 8 9 101112131415 x [g/kg of dry air]

Max connection power

W 385

385 2.5 M5 EC

Max current

NOMINAL POWER (W)

A

2.5 F7 EC

Extract Supply

Filters

Dimensions

Fan Type

0

0

100

200

300

400

l/sec

* Note: ● The figures above have been measured at 500 m 3 /hr and 150 Pa. Please use the Duplexvent Selection Software to calculate measurements at other performance levels.

Right

Left

1700 370 x 275 Front View

Connections

Type

Diameter

Accessories

395

395

0

200 400 600 800 1000 1200 1400

m /hr 3

80

159

159

80

AIR FLOW

670

e1 e2

Outdoor Air Supply Air Extract Air Exhaust Air

Ø 250 mm Shut-off Damper, Flexible Connector

100

Heat Recovery

Supply Air

Extract Air 1000 / 278

Ø 250 mm Ø 250 mm Ø 250 mm

Flexible Connector Flexible Connector Flexible Connector

140

140

140

Maximum air volume @ 200 Pa

m 3 /hr / l/sec 1000 / 278

i1 i2 K

246

246

90

359

359

i2

R250

R250

e2

Air volume @ 150 Pa * Temperature at inlet * Temperature at outlet * Humidity at inlet * Humidity at outlet *

● ●

R250

R250

m 3 /hr / l/sec 500 / 139

500 / 139

Condensate Outlet

Ø 21 mm Condensate Trap

80

150 1100

O C O C

-10

22

17 90 12

2

i1

e1

70

R250

R250

R250

R250

225

225

225

225

%rh %rh

40

K

K

150

150

60

100

80

175

175

80

Accessories See Duplexvent accessories pages 204-206 for more details.

Thermal efficiency in winter / summer Performance in winter / summer

%

84 / 80

Top View

Winter Summer

50 THERMAL EFFICIENCY %

kW

4.6 / -0.6

Weight = 157kg

Condensation

l/h

1.5

40

0

100

200

300

400

l/sec

670

370 x 275

Type of heat exchanger

Counter Flow, Plastic

P art No.

90000183

0

200 400 600 800 1000 1200 1400

m /hr 3

* The above figures are example performance measurements. Please use the Duplexvent Selection Software to calculate measurements at other performance levels.

* Note: ● The figures above have been measured at 500 m 3 /hr and 150 Pa. Please use the Duplexvent Selection Software to calculate measurements at other performance levels.

AIR FLOW

+ Excludes motors

airflow.com

Customer Services 01494 560800

airflow.com

180

181