ABB_PMA_Catalogue_English V20 with links
PMA OVEREXTRUDED CONDUITS - TYPE JFBD & JXPCSF CONDUIT
29
— PMA overextruded conduits Type JFBD & JXPCSF conduit
— Type JFBD - Flexible, medium-duty
Stat. radius (mm)
Dyn. radius (mm)
Conduit size Inside Ø (mm)
Outside Ø (mm)
PU (mm)
Order no.
NW Metric
JFBDT-12C01 JFBDG-17C01 JFBDG-23C01 JFBDG-29C01 JFBDG-36C01 JFBDG-48C01
12 17 23 29 32 48
16 20 25 32 40 50
12.0 15.7 21.8 27.6 36.3 47.3
16.0 21.5 28.7 34.9 43.0 54.8
40 55 75 90
100 125 170 210 260 330
50 50 50 50 30 30
JFBD
110 140
Smooth easy to clean out layer High reversed bending stresses
Approvals
Excellent flexibility in combination with high strength High resistance to chemicals and cleaning agents For indoor food zone – non contact Outer layer made from FDA compliant material Corrosion free
JFBD Index min. Ductility
Materials
Colour
max.
Conduit: made from high-grade, specially formulated polyamide 12
Corrugated conduit: blue Overextrusion: made from modified polyamide elastomer Overextrusion: blue, translucent Certification UV Resistance FDA 21 CFR / EU 10/2011 compliant outer layer material; ECOLAB certificate -
Fatigue reversed bending Compression resistance Low temperature performance Weathering resistance
1
— Type JXPCSF - Highly flexible, heavy-duty — TECHNICAL DATA SHEET PMA OXC - JXPCSF - Over-extruded Conduit Highly flexible, heavy-duty
Stat. radius (mm)
Dyn. radius (mm)
Conduit size NW Metric
Order no. (black/orange) JXPCSFT-12BO JXPCSFG-17BO JXPCSFG-23BO JXPCSFG-29BO JXPCSFG-36BO JXPCSFG-48BO
Profile (T/G)
d1 (mm)
d2 (mm)
d3 (mm)
Weight (kg/100m)
PU (m)
JXPCSF PMA® Cable Protection
T
12 17 23 29 36 48
16 11.8 15.6 16.0 20 15.5 21.1 21.6 25 21.5 28.4 28.8 32 27.4 34.5 34.8
40 55 75 90
100 125 170 210 260 330
4.9 50 8.6 50 13.5 50 16.7 50 21.6 30
Over-extruded conduit for rail applications designed specifically to prevent the accumulation of ice under extreme climate conditions.
G G G G G
40 36.0 42.4 42.8 110 50 47.1 54.5 54.8 140
29.4 30 Over-extruded conduit for rail applications designed specifically to prevent the accumulation of ice under extreme climate conditions For dynamic or static external applications in railway vehicles - on the roof, between carriages and on bogies Excellent flexibility. Smooth outer layer prevents accumulation of ice Easy cleaning and high resistance to chemicals and cleaning agents. Compatible with PMAFIX Pro and accessories EN 45545-2 HL3 (R22 & R23) Colour: • Conduit outer layer: black, Inner layer: orange • Overextrusion: black Product selection: Part no. Profile Conduit size NW metric black T/G
JXPCSF Index min. Features & Benefits: • Excellent flexibility • Self-extinguishing • Smooth outer layer prevents accumulation of ice • Easy cleaning • High resistance to chemicals and cleaning agents Materials: • Multi layer conduit: specially formulated polyamide 12 • Overextrusion: specially formulated polyamide 12 Ductility Fatigue reversed bending Compression resistance Low temperature performance Weathering resistance Compatible with: • PMAFIX Pro and accessoriess Temperature range: • –50°C ... +95°C continuous, +150°C short-term Conforms to: • EN 45545-2 HL3 (R22 & R23) Weathering resistance: • Excellent UV resistance and weathering characteristics Applications: • For dynamic or static external applications in railway vehicles • On the roof, between carriages and on bogies
Dime
Chemical properties: • Please refer to www.pma.ch
d1
d2
Materials
Temperature range JXPCSFT-12BO T
Colour 16
max.
Environmental properties: • Free from halogens and cadmium • RoHS and REACH compliant
12 17
11.8 15.2 21.5 27.7 35.8 46.8
15.8 21.2 28.5 34.4 42.4 54.4
JXPCSFG-17BO
G
20
2 2 3 4
Multi layer conduit: specially formulated polyamide 12 Overextrusion: specially formulated polyamide 12
–50oC to +95o C Black/Orange JXPCSFG-23BO G 23 25
Short-term to: +150o C JXPCSFG-29BO G JXPCSFG-36BO G
29 36 48
32
40 50
JXPCSFG-48BO 5 Our customer service dept. or local distribution partner will be pleased to help you concerning produc G
JXPCSF-Index min.
max.
Certification
Fire performance UV Resistance
Ductility
Free from halogens and cadmium
Self-extinguishing
Excellent
Fatigue reversed bending
Compression resistance
RoHS and REACH compliant
Low temperature performance
Weathering resistance
TDS - JXPCSF - 16322-01
stat. R. = lowest recommended bending radius for static (fixed) installation
dyn. R. = lowest recommended bending radius for dynamic (flexible) instal -
Made with FlippingBook - Online Brochure Maker